Zennio KLIC-DD v3 User Manual

Knx - daikin gateway for domestic range daikin a/c units

Advertisement

KLIC-DD v3
KNX - Daikin Gateway for
Domestic Range Daikin A/C Units
ZCLDDV3
Application program version: [1.1]
User manual edition: [1.1]_a
www.zennio.com

Advertisement

Table of Contents
loading

Summary of Contents for Zennio KLIC-DD v3

  • Page 1  KLIC-DD v3 KNX - Daikin Gateway for Domestic Range Daikin A/C Units ZCLDDV3 Application program version: [1.1] User manual edition: [1.1]_a www.zennio.com...
  • Page 2: Table Of Contents

    KLIC-DD v3 CONTENTS Contents ............................2 Document Updates ........................3 Introduction .......................... 4 1.1 KLIC-DD v3 ........................4 1.2 Installation ........................5 1.3 Start-Up and Power Loss ....................6 Configuration......................... 7 2.1 General ..........................7 2.2 AC Gateway ........................9 2.2.1...
  • Page 3: Document Updates

    KLIC-DD v3 DOCUMENT UPDATES Version Changes Page(s) Changes in the application program: AC unit operation time counter. Temperature measured by the A/C Unit. Advanced climate control through external reference temperature. LED notification of internal errors. Optimisation of the Heartbeat, binary inputs, temperature probe and motion detector module.
  • Page 4: Introduction

    KLIC-DD v3 1 INTRODUCTION 1.1 KLIC-DD V3 KLIC-DD v3 from Zennio is a gateway that provides full-duplex communication between the KNX home automation system and domestic range Daikin air-conditioning systems through the S21 port of interior units. KLIC-DD v3 adds component improvements and electrical safety over the previous KLIC-DD3.
  • Page 5: Installation

    Communication cable (4): 5-wire cable with S21 connector that will connect KLIC-DD v3 and the A/C unit. The other end of the cable, therefore, is intended to be connected to the S21 connector in the PCB board of the internal unit.
  • Page 6: Start-Up And Power Loss

    Important: Control the A/C unit both through its incorporated wired remote control and through KLIC-DD v3 is not possible, due to both of them use the S21 port. By the other hand, if the wireless control is employed, it must be considered that orders sent from the wireless control will have a higher priority than those sent through KLIC-DD v3.
  • Page 7: Configuration

    The “General” screen is shown in the first place, containing the following parameters: Figure 3. General. AC Gateway [enabled] : entails all functions specific to KLIC-DD v3, relating to communication with the A/C unit and management of the climate control system. For more information, see section 2.2.
  • Page 8 KLIC-DD v3 Figure 4. Heartbeat. Note: the first sending after download or bus failure takes place with a delay of up to 255 seconds, to prevent bus overload. The following sendings match the period set. Regardless of the above parameters, the following objects are available by default: “[AC] On/Off”...
  • Page 9: Ac Gateway

    KLIC-DD v3 allows controlling and monitoring an air-conditioning unit in the same way it would be through the wired remote control it is provided with. Through the KNX bus, KLIC-DD v3 can be sent orders to control the following basic functions of the air conditioning unit: On/Off switch of the air-conditioning unit.
  • Page 10 These functionalities imply changes in the state of the A/C unit, which therefore notifies KLIC-DD v3 periodically about the current state. When KLIC-DD v3 is notified about a change, it updates the status objects and sends them to the KNX bus. In addition, KLIC- DD v3 provides an error management function (see section 2.2.4), which allows...
  • Page 11 KLIC-DD v3 OPERATION MODES KLIC-DD v3 allows controlling the A/C unit operating mode through the following objects, available by default: “[AC] Mode”: 1-Byte object which allows selecting the A/C unit operation mode. There will be only taken in account values that are appropriated with some of available modes in Daikin units, which are represented in Table 1.
  • Page 12 The Fan function allows sending the A/C unit orders to switch the ventilation speed along the available levels (5 levels and automatic mode). To that end, KLIC-DD v3 provides a percentage control through the objects “[AC] Fan: percentage control” y “[AC] Fan: percentage control (Status)”, available by default.
  • Page 13 KLIC-DD v3 Control Value Status Value Sent level to the A/C unit Automatic mode 1-20% 1 (minimum) 21-40% 41-60% 61-80% 81-100% 100% 5 (maximum) Table 2: Fan Speed. In addition, automatic fan speed mode can be activated through the following parameter: Individual Object for Automatic Mode [disabled/enabled]: enables the “[AC]...
  • Page 14 KLIC-DD v3 TEMPERATURE MEASURED BY THE A/C UNIT Monitoring [disabled/enabled]: enables the “[AC] AC Unit Measured Temperature” two-byte object, which provides the value of its internal temperature sensor, which is used by the AC machine to execute the control loop. Once enabled, a secondary parameter will show: ...
  • Page 15 Heating and Auto modes), provided that the limits are still within the predefined limits of the A/C unit. When KLIC-DD v3 receives an order to send the A/C unit a setpoint which is greater (or lower) than the configured limits, it will actually send the limit value.
  • Page 16 The A/C unit set a fixed temperature setpoint in Fan and Dry mode, this is the reason why KLIC-DD v3 will not send the setpoint value to A/C unit, however the value will be saved to send when leaving these modes.
  • Page 17 KLIC-DD v3 If a new external temperature value is received, the control will be again executed by using this external value. The allowed value range is [0-70] ºC (if different values are received, they will be ignored). Actually, the machine will continue to executing its control loop with the same reference...
  • Page 18 KLIC-DD v3 Control Status Level Sent Level Description Value Value to A/C unit Control Humidity Off 1-25% Humidification/dehumidification with low energy 26-50% Standard Humidification/dehumidification with moderate energy 51-75% High Humidification/dehumidification with high energy 76-100% 100% Continuous Continuous humidification/dehumidification Table 4. Humidity operation levels.
  • Page 19 KLIC-DD v3 Humid heating operation: this operation permits to raise the temperature and humidity. The ways to active this operation are:  While in Heating mode, modifying the humidity adjust.  While in Ururu humidification mode, modifying the temperature setpoint.
  • Page 20 During the temporary switch-off state, KLIC-DD v3 will still monitor any control orders being received (setpoint, fan speed, etc.), so they can be applied once it leaves such state.
  • Page 21 Initial Configuration: allows setting the desired initial state that KLIC-DD v3 will send the A/C unit after programming or restarting the device:  Default: the initial state will be the last one KLIC-DD v3 is aware of.  Custom: see section 2.2.2.
  • Page 22: Initial Configuration

    2.2.2 INITIAL CONFIGURATION The custom initial configuration allows setting the desired status that KLIC-DD v3 will send the A/C unit after downloading or restarting the device. This status is defined in terms of on/off, mode, fan speed, flaps position and temperature setpoint.
  • Page 23 KLIC-DD v3 [Last (Before Restart) / Automatic / 1 / 2 / 3 / 4 / 5]. Horizontal Flaps [Last (Before Restart) / Swing Off / Swing On]. This option only will be visible in case of having enabled this kind of flaps; on the contrary this section will appear as “Not Available”...
  • Page 24: Scenes

    2.2.3 SCENES The Scenes function allows defining a set of statuses (in terms of On/Off, mode, fan speed, etc.) that KLIC-DD v3 will send to the A/C unit whenever it receives the corresponding scene values from the KNX bus. ETS PARAMETRISATION After enabling this function (see section 2.2.1), a new tab named Scenes will be...
  • Page 25 KLIC-DD v3  Mode [No Change / Automatic / Heating / Cooling / Fan / Dry].  Fan [No Change / Automatic / 1 / 2 / 3 / 4 / 5].  Horizontal Flaps [No Change / Swing Off / Swing On] (if this kind of flaps is available, on the contrary this section will appear as “Not Available”).
  • Page 26: Error Handling

    KLIC-DD v3 2.2.4 ERROR HANDLING KLIC-DD v3 is capable of managing two error types that do not entail any previous parameter configuration: Communication or internal errors: errors in the communication process between KLIC-DD v3 and the A/C unit. These types of errors are notified by the green LED as indicated below: ...
  • Page 27: Inputs

    Important: older models of the Zennio motion detector (e.g., ZN1IO-DETEC and ZN1IO-DETEC-N) will not work properly with KLIC-DD v3. 2.3.1 BINARY INPUT Please refer to the “Binary Inputs” user manual, available in the KLIC-DD v3 product section, at the Zennio website (www.zennio.com). 2.3.2 TEMPERATURE PROBE Please refer to the “Temperature Probe”...
  • Page 28 Motion detectors with references ZN1IO-DETEC and ZN1IO-DETEC-N are not compatible with KLIC-DD v3 (may report inaccurate measurements if connected to this device). When connected to KLIC-DD v3, the rear micro-switch of model ZN1IO- DETEC-P should be set to position “Type B”. http://www.zennio.com Technical Support: http://support.zennio.com...
  • Page 29: Logic Functions

    Please refer to the “Logic Functions” user manual (available in the KLIC-DD v3 product section at the Zennio homepage, www.zennio.com) for detailed information about the functionality and the configuration of the related parameters.
  • Page 30: Annex I. Communication Objects

    KLIC-DD v3 ANNEX I. COMMUNICATION OBJECTS “Functional range” shows the values that, with independence of any other values permitted by the bus according to the object size, may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application program itself.
  • Page 31 KLIC-DD v3 1 Bit C - - W - DPT_Switch [AC] Sarara 0 = Sarara Off; 1 = Sarara On 1 Bit C T R - - DPT_Switch [AC] Sarara (Status) 0 = Sarara Off; 1 = Sarara On [0]% = Off; [0.4 ... 25.1]% = Low; [25.5 ...
  • Page 32 KLIC-DD v3 1 Bit C T R - - DPT_Alarm [AC] Internal Error: Communication Unable to Set AC Communication [AC] Internal Error: Wrong 1 Bit C T R - - DPT_Alarm Acknowledgement Received with Errors Acknowledgement 1 Bit C T R - -...
  • Page 33 KLIC-DD v3 100%) 0x7 (Dec. by 1%) 0x8 (Stop) 0xD (Inc. by 100%) 0xF (Inc. by 1%) 1 Bit C T - - - DPT_Switch [Ix] [Short Press] Light On Sending of 1 (On) 1 Bit C T - - -...
  • Page 34 KLIC-DD v3 0x0 (Stop) 0x1 (Dec. by 100%) 4 Bit C T - - - DPT_Control_Dimming 0x7 (Dec. by 1%) [Ix] [Long Press] Darker Long Pr. -> Darker; Release -> Stop 0x8 (Stop) 0xD (Inc. by 100%) 0xF (Inc. by 1%) 0x0 (Stop) 0x1 (Dec.
  • Page 35 KLIC-DD v3 1=Comfort 2=Standby Auto, Comfort, Standby, Economy, Building 65, 94 1 Byte C T R - - DPT_HVACMode 3=Economy [Ix] Presence State (HVAC) Protection 4=Building Protection 1 Bit C T R - - DPT_Occupancy [Ix] Presence State (Binary) Binary Value...
  • Page 36 KLIC-DD v3 167, 168, 169, 170, 171, 172, 173, 174, 2 Bytes C - - W - 1.xxx [LF] (2-Byte) Data Entry x 2-Byte Data Entry 175, 176, 177, 178, 179, 180, 181, 182 183, 184, 185, 186, -2147483648 -...
  • Page 37 Join and send us your inquiries about Zennio devices: http://support.zennio.com Zennio Avance y Tecnología S.L. C/ Río Jarama, 132. Nave P-8.11 45007 Toledo (Spain). Tel. +34 925 232 002. www.zennio.com info@zennio.com...