M) Emergency stop button: safety
control that, in case of an imminent
risk, stops all parts whose function
might constitute a risk.
– The control must stay "locked" until
all the normal operating conditions
have been restored.
– After having normalised running con-
ditions, unblock the button with a de-
liberate action to authorise restart.
N) Illuminated button (blue light):
control designed to activate electric
power supply.
– Control enabled only when selector
P is in position "1" (ON).
– Blue light off: activated power supply
line.
– Blue light on: power supply deacti-
vated.
P) Key selector switch: safety control
that connects and disconnects the
power supply of battery.
– Position "1" (ON): power supply on
– Position "0" (OFF): power supply off
Q) Key selector: control to activate and
deactivate brake of the machine in-
feed electric motor.
– The key of control must be hand-
ed over to the maintenance tech-
nician in order to avoid any inter-
ference by non-authorised personnel.
– Position "0": brake of electric motor activated and machine functions enabled.
– Control rotated to the right: brake of electric motor deactivated and machine functions
disabled.
– When the machine stops and display E shows "b0", it means that batteries are com-
pletely exhausted.
Important
ONLY the maintenance technician is allowed to release the brake of the electric
motor in order to move the machine to the charge area.
R) Buttons: non-release controls that manually move the machine.
Controls are enabled only when reel holding carriage is in its lowest position.