SUN2000-(3KTL-12KTL)-M0
User Manual
Figure 5-8 Securing the AC connector
Step 3 Check the route of the AC output power cable.
Figure 5-9 Cable route
----End
Disconnection
Disconnection can be performed in reverse order.
5.4 Connecting the DC input power cable
Precautions
Issue 01 (2018-12-30)
Before connecting the DC input power cable, ensure that the DC voltage is within the safe
range (lower than 60 V DC), and that the DC SWITCH is set to the OFF position. Failure
to do so could generate high voltage, which may cause electric shocks.
When the SUN2000 is operating, it is not allowed to operate the DC input power cable,
such as connecting or disconnecting a PV string or a PV module in a PV string. Failing to
do so may cause electric shocks.
If no PV string is connected to a DC input terminal of the SUN2000, do not remove the
watertight cap from the terminal. Otherwise, the IP rating of the SUN2000 will be
affected.
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
35