ProLiant 1850R Interlock Kit Installation Information
EK-1850R-IN. A01
May 1999
Introduction
The 2T-QINTL-18 interlock kit contains the components for installing the slide assemblies, the interlock system,
and the shipping bracket on the rackmounted ProLiant 1850. The interlock system helps prevent cabinet instability
by allowing only one system at a time to be pulled out of the cabinet. The shipping bracket is used to secure the
ProLiant 1850 in the cabinet during shipment or when moving the cabinet to a new location.
The interlock system consists of a vertical rod, on which are mounted actuator latches for each product installed in
the cabinet. These actuator latches engage the interlock actuator on the rear of rackmount systems. When a
rackmount system is pulled out of the cabinet, the actuator latches rotate to prevent any other rackmount system that
has an interlock actuator from being pulled out of the cabinet.
Table 1 lists the parts that are shipped with the 2T-QINTL-18 interlock kit. The callouts in column 1 refer to the part
location in Figure 1.
Table 1 2T-QINTL-18 Interlock Kit Parts List
Figure 1
Description
Callout
24 inch slide assembly
š
Slide bracket, right front and left rear
Slide bracket, right rear and left front
œ
8-32 pan-head screw

Flat washer, .190ID x .051THK
ž
Split washer, .171ID
Ÿ
8-32 hex nut
 
Interlock actuator
¡
Actuator latch
¢
Stabilizer bracket

10-32 threaded nut bar

10-32 truss-head screw
6-32 truss-head screw
Flat washer, .286ID x .066THK
Split washer
Shipping bracket
Flat washer, .221ID x .051THK
10-32 Kep nut
ProLiant 1850R Interlock Kit
Installation Information
© Compaq Computer Corporation. 1999. All Rights Reserved.
®
Compaq, ProLiant, and the Compaq logo are registered in the United States Patent and Trademark Office.
Part Number
Qty.
30-56075-01
1 pair
74-53881-01
2
74-53881-02
2
90-06038-01
8
90-06660-00
8
90-06690-00
8
90-06561-00
8
74-53871-01
1
74-48997-02
1
74-48996-01
1
74-48998-01
1
90-00063-39
4
90-00063-10
2
90-06676-00
2
90-07797-00
2
74-53874-01
1
90-06664-00
2
90-06565-00
2
EK-1850R-IN
1

Advertisement

loading

Summary of Contents for Compaq 2T-QINTL-18

  • Page 1 Table 1 lists the parts that are shipped with the 2T-QINTL-18 interlock kit. The callouts in column 1 refer to the part location in Figure 1.
  • Page 2 Installing the Slide Assemblies The rackmount ProLiant 1850 requires 13.34 cm (5.25 in.) of vertical space or nine contiguous holes in a 48.26-cm — (19-in) EIA cabinet.. The bottom hole in this installation area is identified as hole 1 and the top hole is identified as hole 9 (see Figure 1).
  • Page 3 6-32 set screws to secure the actuator latch to the vertical rod. 9. Now tighten the screws to secure the vertical rod’s bottom mounting bracket. Figure 1 Installing the 2T-QINTL-18 Interlock Kit LJ-06683...
  • Page 4 Installing the Shipping Bracket In the following installation procedures, directions are referred to while viewing the rackmount ProLiant 1850 from the rear of the cabinet. The shipping bracket is used to secure the ProLiant 1850 in the cabinet during shipment or when moving the cabinet to a new location.