5. PRODUCT INSTALLATION

Important notes and advice:
- To make the most of your intercom panel, we recommend configuring it (for 1 or 2
families, 1 or 2 intercoms, loudspeaker volume) before final installation. To do this, a table
connection may be necessary to check that the settings are correct.
- If you test your product before installing it, ensure that you do not test it with the intercom
panel and the monitor in the same room to avoid the videophone emitting a shrill noise
(feedback).
- Do not expose the camera lens to direct sunlight or a reflective surface.
- We recommend running the cables through a protective sheath to protect them against
breakage and bad weather.

1. Wiring.

To avoid the risk of interference and malfunctions, do not run the videophone cable through
the same sheath as the electrical cables.
Warning:
Do not double up the wires to increase their section.
a. Connecting the videophone (monitor, intercom panel and camera, see fig. 1, fig. 2 and fig. 3)
Wires to be used: 2 wires 0.75 mm
- Make sure to connect the wires in accordance with one of the wiring diagrams depending
on the desired configuration.
- Refer to the label stuck to the back of the monitor and the back of the intercom panel.
- Configure the switches on the back of the intercom panel as well as the monitor interface
according to the chosen configuration (see section 2 intercom configuration).
b. Connecting a gate motor
The camera delivers a dry contact with no current, to be connected to the push button
control of your automatic opener.
- Connect it directly to terminals 5 and 6 at the back of the intercom panel (no need to
observe polarity).
- The opening function is only possible if the video of the respective intercom panel is
displayed.
c. Connecting a strike plate or electric lock
Important:
The strike plate or electric lock that you are ordering must have a mechanical
memory. The strike plate current cannot exceed 1.1A.
- Connect it directly to terminals 7 and 8 at the back of the intercom panel (no need to
observe polarity).
- The opening function is only possible if the video of the respective intercom panel is
displayed.
2. Configuring the intercom (see fig. 1, fig. 2 and fig. 3)
a. Configuring the intercom number:
Place switch 2 on the left on intercom no. 1 and on the right on intercom no. 2.
GB5
with 80 m length or 2 wires 1.5 mm
2
WelcomeEye Comfort / Compact / 08/17
with 120 m length.