Tech Mode - Frymaster LOV Technical Information Manual

Hide thumbs Also See for LOV:
Table of Contents

Advertisement

1.6 Tech Mode

Tech mode allows technicians to reset passwords set in levels one and two. It also resets the
time and date. It also allows the technician to access the fryer main setup mode.
1. Press and hold
CODE is displayed.
2. Enter 1650.
3. The computer displays TECH MODE and changes to CLEAR PASSWORDS.
4. Press the
(1) button to accept selection and clear the passwords.
5. The computer displays CLEAR PASSWORDS on the left and COMPLETE on the
right. This clears any passwords set up under levels one and two.
u
button to toggle to CLEAR SIGNATURE.
6. Press the
7. Press the
(1) button to accept the change.
8. The computer displays CLEAR SIGNATURE on the left and COMPLETE on the
right. This resets the date and time.
u
button to toggle to FILTER PAD TIME on the left and 25 on the right.
9. Press the
(25 hours is the default time to change the pad)
10. Press the
(2) button to accept changes and exit.
11. The computer displays OFF. Proceed to the next page to enter the setup mode.
3
4
and
simultaneously for TEN seconds until a third chirp is heard and
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents