LOV
Quick Start:
A: Filter light:
Illuminates
when it's time to
filter.
B: M3000: Programmable
for automatic filtering.
Press
1(YES) button to
respond YES to filter
prompt.
C: MIB: Displays status of
system.
NOTE: The Frymaster LOV™ fryer requires a start-up, demonstration and training before
normal restaurant operations can begin.
E: JIB light: Illuminates when oil
reservoir is low.
D: Power switch: One in cabinet under
each computer (domestic electric only).
1. Turn on power switches (D).
2. Fill vats to lower fill line.
3. Turn computers on using the
4. Computer displays "CHANGE
YES/NO"
5. Press
1 (YES) and computer displays "REMOVE
PAN"
6. Remove pan and computer displays "CHANGE FIL-
TER PAD"
7. Assemble filter pan, ensuring pan is out 30 seconds.
Re-install filter pan.
8. Position JIB (Jug in a Box) in the right cabinet, placing
pick-up tube in open jug (G).
9. Press and hold the JIB reset switch until light goes out.
(F).
10. Ensure A is showing on the display of the MIB. A P in-
dicates the filter pan is not properly placed. Reseat the
filter pan if necessary.
11. While cooking, respond YES to the Filter Now Prompt
in display (B) and illuminated blue light (A) by pressing
the
1 (YES) button.
12. Respond to the JIB light (E) by replacing the JIB (G)
and resetting (F) or refilling the JIB with RTI system.
F: JIB reset button: Press and
hold after replacing the JIB until
yellow light goes out..
G: JIB: Jug in a Box, holds oil for auto-
matic top-off system. It's not used to fill
the vats, just to maintain the oil level. Use
only fresh oil in top off system.
2-10
button.
FILTER PAD?
819-6452