User Manual MAGICFX® Stage Flame

10. READYING FOR USE

Prepare the Stage Flame for use as follows:
1.
2.
3.
Page 13
CAUTION:
This indicates that the equipment may be damaged if procedures are not
carried out in the proper manner.
DANGER WARNING:
The MAGICFX® Stage Flame may only be worked on by authorised
adults.
Place the Stage Flame on a flat, solid, and
stable surface.
For indoor use with aerosol cans, the
minimum clearance height above the Stage
Flame is six meters. For indoor use with gas
bottles, the minimum clearance height is
seven meters.
For Big Flame mode, the minimum clearance
height is at least ten meters.
Ensure the Power button is set to "off".
Connect the power cable. The Stage
Flame runs on 230V~ 50/60Hz.
You can use a powerCON link cable to
connect multiple Stage Flame devices up
to the same power source.
Connect a 3-pole DMX cable to the Stage
Flame.
Optionally, you can link multiple Stage
Flames together using 3-pole DMX
cables.