Page 1
User Guide MOTOmed viva2, MOTOmed letto2 - valid as of software version 5.03 – status September 2011...
Page 2
Please use the MOTOmed only after you have read the uiser guide. If you should not understand the language of the present version, please request the instruction manual in your native language. Benutzen Sie das MOTOmed erst, nachdem Sie die Gebrauchsanweisung gelesen haben.
Page 3
Please refer to the instruction manual 713/W2559 in order to find information about the usage of the MOTOmed viva2, gracile12 and letto2 as well as our wide range of accessories. If you have further questions or comments, please do not hesitate to call your MOTOmed representative or the RECK customer service team.
Operation page Operating panel Operating modes Foot insertion aid Standard mode Start screen Quick start Menu structure Menu navigation (user guidance) Program selection Training screens Key lock Training menu SpasmControl and MovementProtector Automatic performance control Set starting parameters MOTOmed analysis Device settings Expert mode Accessing expert mode...
Page 6
Operating panel Operating modes The new MOTOmed viva2 software provides two different operating modes. »standard mode« is suitable for most MOTOmed users and offers a simple and quick access to the basic functions and settings which are needed for a regular use of the MOTOmed movement therapy.
In order to get back to the start screen from any menu, please push button (during the training additionally push button »restart«). Quick start MOTOmed viva2/gracile12 MOTOmed letto2/letto2 leg/arm fig. 2/ 3 By pushing button »arm trainer« or button »leg trainer« you...
Page 8
Menu structure The start screen (in standard mode) provides the following menu options: Program menu Settings menu button see page 9 button see page 21 1 standard program 2 language 2 MOTOmax 3 display and volume (MotivationProgram) 4 device settings 3 TRAMPOLINEmax 5 information 4 loosening program...
Page 9
Program selection From your MOTOmed operating panel or your chip card (accessory), you can select any of the therapy programs available. For this purpose access the program menu or insert your MOTOmed chip card into the card reader of your MOTOmed operating panel. The following programs are available in the standard mode (base settings can be adjusted during the training, but cannot be saved permanently):...
Start a program from your MOTOmed chip card: If you have a MOTOmed chip card with a saved program, this program will load automatically once the chip card is inserted. 1 Standard program The standard program is the most simple way to train with the MOTOmed.
Page 11
Champion points (strength and endurance): You can collect champion points by staying on the colored podium. The lowest red level provides the least number of points. On the yellow level you achieve twice the number of points and on the highest green level you can collect triple points.
Page 12
3 TRAMPOLINE max (MotivationProgram) Max should collect as many stars as possible in the time given. The game can be played with the arms or the legs. stars to be level collected game character Max jumping direction the trampoline is being moved to the right or to the fig.
Page 13
5. If no star has been collected within 30, 35 or 40 seconds (depending on the difficulty level), a new star appears. 6. If Max hits the ground, it falls back to the previous level. 7. If you stop training actively, Max falls asleep and pauses. However, the timer continues and stars reappear.
Page 14
Target assistance: If target assistance is activated, Max jumps automatically towards the right direction when only one star is left to collect. Thus the last star can be collected easily. Difficulty levels: The game can be played in 3 different difficulty levels. The size of the trampoline, the speed of the character and the time it takes until new stars reappear can be changed in the the settings.
Page 15
4 Loosening program Special sequences of passive movement help you to loosen and relax your muscles. The special MOTOmed MovementProtector provides a smooth, gentle movement which can help you to reduce your muscle stiffness (tone) and ease the spasticity symptoms, and loosen daily tensions. 5 Strengthening and endurance The strengthening and endurance program is a special training sequence, connecting basic endurance training with a strengthening...
Page 16
Training screens You can adjust the most important settings for your training (passive speed and gear) without having to pause the training. During the passive training (the motor of the MOTOmed is moving your legs/ arms) you may adjust the training speed at any time with button »slow«...
Page 17
menu selection with button 1 by pushing button 2 you can freeze the display alternating display function: alternating display information can be activated SpasmControl »on« (green flash symbol) SpasmControl »off« (gray, crossed out flash symbol) total training time remaining time in a phase (only in therapy programs) passive speed in revolutions/min.
Page 18
Training menu If you wish to make further adjustments (e.g. training time, SpasmControl, pulse control, ...) during the training, push button »menu«. Thereby you enter the training menu (fig. 19). As soon as you are in the training menu, the MOTOmed goes into pause and the pedals cannot be moved anymore.
Page 19
The sensitivity of the SpasmControl can be adjusted in the settings menu in the devices settings or during the training in the training see page 21 menu. With the »sensitive« setting, the MovementProtector is already activated even after a short movement blockade (e.g. spasm), while on the contrary it has a longer reaction span with the setting »less sensitive«.
Page 20
Set starting parameters In order to configure the starting parameters (e.g. SpasmControl, revolutions, duration, resistance level, flywheel mass,...) of the »standard program« follow these instructions: 1. Start the standard program and access the training menu by see page 18 pushing button »menu«...
Page 21
Device settings Basic settings of your MOTOmed (device settings, display/volume, date/ time, ...) can be adjusted in the setup menu (fig. 22). Go to the start screen and push button »setup«. Access via Use the buttons ( / ) to start screen select the desired menu item.
(display black, green start light active). fig. 24 Push the buttons in quick succession. MOTOmed viva2/gracile12 MOTOmed letto2/letto2 leg/arm fig. 25/ 26 The MOTOmed starts in expert mode, on the start screen the information »expert mode active« is shown above the program name.
Page 23
Program package 1: therapy goals 1 standard program 2 MOTOmax (MotivationProgram) 3 TRAMPOLINE max (MotivationProgram) 4 loosening program 5 strengthening and endurance 6 coordination program Program package 2: specialty fields 1 standard program 2 PC games 3 FES program (especially for muscular stimulation) 4 ortho (suggestion for orthopedic patients) 5 neuro (suggestion for neurological patients) 6 cardio (program suggestion for cardiological patients)
Page 24
In order to load another program package, proceed as follows: 1. Access the start screen in the expert mode (page 22, fig. 25/ 26) and push button Access via »programs«. the program 2. Use button ( / ) to menu in the select line 8 »program packages«...
Page 25
Program parameters define the basic settings of a program (e.g. name, number of phases, SpasmControl »on/off« etc.) and are valid for all phases. Phase parameters on the other hand define the content/ characteristics of each phase (e.g. training task, phase duration (min/ sec), passive speed, etc.) and are valid for the current phase only.
Page 26
9 sound at end of phase 10 display of phase change [sec] 11 segment filter setting 12 change in speed/gear 13 serial interface (optional) 14 repetitions 15 display If you wish to save your changes push button »back«. The programming menu (fig. 28) appears. Save your changes by marking see page 24 line 3 »save changes«...
Page 27
Standard active: The user is encouraged to pedal actively. Standard passive: Allow the motor to move the legs/arms of the user. SymmetryTraining: Both legs (arms) shall be used actively. The stronger and weaker side of the body is being measured and the results are displayed on the screen by two bar graphs (the push movement is measured) in order to achieve a balanced training.
Page 28
11 crank configuration (parallel 14 save changes to all phases mode) 15 copy function to other phases 12 delete current phase (only 16 go to next phase if more than one phase is 17 go previous phase available) 13 duplicate current phase (imported after current phase) If you wish to save your changes push button »back«...
Page 29
Programming example Select and edit an available MOTOmed program in order to create an individual therapy program (e.g. »loosening program«) At first, specify the program characteristics (program parameters) followed by the characteristics/content of the individual phases (phase parameters). Starting point: The MOTOmed is in stand-by-mode (display black, green start light active) 1.
Page 30
3. Access the program parameter menu and adjust the program key sequence parameters ( ) or ( ) or (save changes); »back« fig. 36/ 37 4. Access the phase parameter menu and adjust the phase parameters key sequence »select« ( ) or ( ) or (save changes)
Page 31
6. Go back to the programming menu and save your changes key sequence »back« »OK« fig. 42/ 43 Additional device settings Go to the expert mode start screen (fig. 25/26) and push button see page 22 »setup«. As an addition to the adjustment possibilities already described in the settings menu chapter, the menu items marked in see page 21 bold in the below table are available in expert mode:...
Page 32
Menu point: Sub menu 2 language volume contrast 3 display and screen duration [sec] volume symmetry display pushing right, MOTOmax moves right game character TRAMPOLINEmax show help info screen select info panel coordination program start screen information end of program signal buttons for alternating display 4-Segment bar display (only available if accessory is installed)
Page 33
Accessories/ program additions Chip card menu (item no. 203) With your RECK MOTOmed chip card, you can regularly record your training data and file, evaluate and print it using the »sam2« analysis program or the simple print program »sPrint«. You can save your individual...
1 show status (user) 2 delete data points from chip card 3 save data from chip card to MOTOmed 4 save MOTOmed to chip card 5 format chip card (overwrite) fig. 46 In standard mode you can only access line 1 and 2! 1 Show status: In order to check the status of your MOTOmed chip card (user data, capacity, number, training data points), use the buttons...
Page 35
Push button »chip card« from your expert mode start screen. Use the buttons ( / ) to mark line 3 »save from chip card to MOTOmed« and push button »select«. Mark line 1 »single program« and push button »OK«. Push the red »start/stop« button to return to the start screen.
Page 36
Use the buttons ( / ) to mark line 3 »save from chip card to MOTOmed« and push button »select«. Mark line 3 »system settings« and confirm with button »OK«. Push the red »start/stop« button to return to the start screen.
Page 37
4.3 Save system settings to chip card: Push button »chip card« from your expert mode start screen. Use the buttons ( / ) to mark line 4 »save from MOTOmed to chip card« and push button »select«. Use the buttons ( / ) to mark line 3 »system settings«...
Page 38
4. In the screen provided (fig. 47) use the buttons ( / ) (select letter) to ( / ) (select letter position) to enter your data. With button the text can be deleted from the chosen cursor position. 5. Push button »next«...
Page 39
MOTOmed Cardio16 pulse control (item no. 275 or 276) In order to train at an optimal resistance level at any time, you may allow the pulse control monitor to control your training. For this you can individually define a preferred pulse limit (upper and lower limit). The MOTOmed automatically increases or decreases the resistance level you are training with in order to keep your pulse within your preset pulse range.
Page 40
Following additional information is displayed within the MOTOmed Cardio16 pulse control on the training screen (fig. 48): Menu selection with button pulse monitor »good signal» (heart symbol green) pulse monitor »low signal« (heart symbol orange) »pulse exceeded maximum pulse limit« (red blinking heart symbol) If this value is exceeded for more than 15 seconds the MOTOmed shuts off automatically.
Page 41
Adjustment of pulse control settings Basic settings of the pulse control are adjusted in the settings menu see page 31 (in expert mode) at device settings in the submenu pulse control. These adjustments are valid for all training programs. 1 pulse sensor 2 lower pulse limit 3 upper pulse limit 4 maximum heart rate...
Page 42
In order to adjust the maximum limit proceed as follows: 1. Go to the start screen and push button »setup«. 2. Use the buttons ( / ) in order to mark line 4 »device settings« and push button »select« in order to switch into the submenu device settings.
Page 43
MOTOmed sam2 Training Analysis Program (item no. 230) The training analysis program »MOTOmed sam2« is available for a sophisticated analysis, storage and graphical illustration of your training data. If you only wish to analyze your last training session you can use the simple print program »MOTOmed sPrint«. For this purpose a MOTOmed chip card has to be inserted during training.
Page 44
4-Segment CoordinationProgram (item no. 202) When using the 4-Segment CoordinationProgram you have the possibility to specifically target and train in individual directions and toward muscle groups specifically. In this context various training tasks require different input, such as strength, endurance, coordination and concentration.
Page 45
The 4 different segments (»push«, »down«, »pull« and »up«) can be trained separately, with each other or in different combinations (2 or 3 segments combined). A special success bar gives continuous feedback during training about how adequate you fulfill the task (given by the segment combination) (fig.
Page 46
In order to train a sequence of different segment versions (or training tasks) you can create an optional program on your own (chapter »edit programs«, page 24). If you wish to adjust training tasks during the training, you need to be in the expert mode: fig.
Page 47
Index accessories heart symbols additional programs adjust contrast alternating display information jumps for joy analysis key lock Cardio16 pulse control champion points chip card menu coordination program language option 4-Segment load default settings loosening program date/time device settings menu structure direction MotivationProgram MOTOmax duration...
Page 48
Index passive speed Training Analysis Program performance control training menu performance control training screens (automatic) training tasks phase parameters TRAMPOLINEmax program menu program packages program parameters user guidance quick start volume resistance levels segment versions settings menu SpasmControl spasticity (cramps) standard mode standard program stand-by mode...
Page 50
GB 713/W2558a (entspricht dt. Version "a") 05.12 binSt We reserve the right to technical changes according to the progress. Reprint, also extracts requires a written permission of the RECK Company.