6. Name of every part
Control panel (All machine type community)
⑪
⑦
⑧
②
①
③
⑥
⑲
⑱
①
STOP switch
This is the stop switch of blow operation and hot-air operation,
and for the cancellation of timer operation.
②
HOT-AIR switch
Hot-air operation is started when the switch was pushed.
③
BLOW switch
Blow operation is started when the switch was pushed.
④
OPERATION BY TIMER switch
Time that the operation is started is set up when the switch was
pushed. Please push HOT-AIR switch after setting.
⑤
STOP BY TIMER switch
Time that the operation is stopped is set up when the switch
was pushed. Please push HOT-AIR switch after setting.
⑥
EXT. RUN switch
Hot-air generator is operated with the external operation
signal and external heater ON/OFF signal by the switch is
continued to push (about 2 seconds).
⑦
HOT-AIR TEMP. display
Outlet temp. is displayed. Temp. of the external sensor is
displayed by the operation condition is changed to the
external sensor.
⑧
SETTING TEMP. display
Setting temp. of the outlet is displayed. Setting temp. of the
external sensor is displayed by the operation condition is
changed to the external sensor.
⑨
AIR VOL. COTL display
Setting value of the air volume control (Frequency setting) is
displayed.
⑩
TIMER display
Setting time of the timer is displayed. Time is reduced by time
counting.
⑪
HEATER lamp
ON/OFF of the heater is displayed by illumination and
flickering.
⑫
TEMP. ALM lamp
This is lighted within the range of the temp. alarm setting value
in the case that temp. alarm setting is input.
⑬
EXT. CNTL lamp
This is lighted when the operation condition was changed to
the external control.
⑭
EXT. SENSOR lamp
This is lighted when the operation condition was changed to
the external sensor.
⑮
OVERHEAT lamp
This is lighted and the breaker (NFB) is become trip in the
case that the heater case inside became a abnormal high temp.
⑯
TEMP. WARN. Lamp
Breaker (NFB) is become trip or bloe operation is become in
the case that discharge temp. became a high temp. or suction
temp. became over the permission temp. of the blower.
⑰
BLOWER WARN. Lamp
This is lighted when the blower became the overload and
operation stops.
⑱
PUSH TO TEST
Breaker (NFB) is become trip by the button is pushed.
⑲
MODE switch
This is used in the case that the operation condition is changed.
-4-
⑫
⑬
⑭
⑨
⑩
④
⑤
⑮
⑯
⑰