Hot-air generator, c-type series
Table of Contents

Advertisement

6. Name of every part
Control panel (All machine type community)
STOP switch
This is the stop switch of blow operation and hot-air operation,
and for the cancellation of timer operation.
HOT-AIR switch
Hot-air operation is started when the switch was pushed.
BLOW switch
Blow operation is started when the switch was pushed.
OPERATION BY TIMER switch
Time that the operation is started is set up when the switch was
pushed. Please push HOT-AIR switch after setting.
STOP BY TIMER switch
Time that the operation is stopped is set up when the switch
was pushed. Please push HOT-AIR switch after setting.
EXT. RUN switch
Hot-air generator is operated with the external operation
signal and external heater ON/OFF signal by the switch is
continued to push (about 2 seconds).
HOT-AIR TEMP. display
Outlet temp. is displayed. Temp. of the external sensor is
displayed by the operation condition is changed to the
external sensor.
SETTING TEMP. display
Setting temp. of the outlet is displayed. Setting temp. of the
external sensor is displayed by the operation condition is
changed to the external sensor.
AIR VOL. COTL display
Setting value of the air volume control (Frequency setting) is
displayed.
TIMER display
Setting time of the timer is displayed. Time is reduced by time
counting.
HEATER lamp
ON/OFF of the heater is displayed by illumination and
flickering.
TEMP. ALM lamp
This is lighted within the range of the temp. alarm setting value
in the case that temp. alarm setting is input.
EXT. CNTL lamp
This is lighted when the operation condition was changed to
the external control.
EXT. SENSOR lamp
This is lighted when the operation condition was changed to
the external sensor.
OVERHEAT lamp
This is lighted and the breaker (NFB) is become trip in the
case that the heater case inside became a abnormal high temp.
TEMP. WARN. Lamp
Breaker (NFB) is become trip or bloe operation is become in
the case that discharge temp. became a high temp. or suction
temp. became over the permission temp. of the blower.
BLOWER WARN. Lamp
This is lighted when the blower became the overload and
operation stops.
PUSH TO TEST
Breaker (NFB) is become trip by the button is pushed.
MODE switch
This is used in the case that the operation condition is changed.