8-3 Blower warning
All the operation of hot-air generator is stopped when the blower became overload, overcurrent, and lock.
●
At the time of the blower warning
The position of the inverter panel differs by the machine type.
*1
・
TSK-18
・
・
TSK-23
33
・
・
TSK-42
52
・
TSK-52HT
・
TSK-56
・
・
TSK-62
72
・
TSK-82
・
・
TSK-92
102
・
・
TSK-122
132
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.
:
Back side of the control panel service terminal
:
The inside of the back panel
:
The inside of the control panel (Please open the control panel and please confirm.)
:
The inside of the back panel
:
The inside of the control panel (Please open the control panel and please confirm.)
:
The inside of the back panel
:
The inside of the back panel
:
The inside of the back panel
:
The inside of the grid window of he control panel
BLOWER WARN. lamp (Red) is lighted and "InV" is
flickered to HOT-AIR TEMP., "ALM" to SETTING
TEMP.
《
》
Main cause
・
Wear of the bearing
・
Abnormal voltage (Voltage more than the rating)
・
Piping of many pressure loss
・
Opening the use of an extremely narrow nozzle
《
》
Return method
Abnormality is displayed to the inverter panel *
that was established inside. Please turn off the
breaker of this machine after the display contents
are confirmed. And, please communicate the
display contents.