At the time of the burnout of the inlet sensor
●
At the time of the inside temp. warning of the hot-air generator
●
At the time of the inside SSC temp. warning of the hot-air generator (Only TSK-122, 132 200V)
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.
TEMP. WARN. lamp (Red) is lighted and "---" is
flickered to HOT-AIR TEMP., "Tcc" to SETTING
TEMP. And, all the operation stop.
《
》
Main cause
・
Snapping of a wire of the inlet sensor
・
Snapping of a wire of the inlet sensor wiring
・
Miss of the inlet sensor wiring connector
《
》
Return method
Please order the repair after turning OFF the
breaker (NFB) of the this machine.
TEMP. WARN. lamp (Red) is flickered and "OH" is
flickered to HOT-AIR TEMP., "ALM to SETTING
TEMP. And, It becomes blow operation condition.
《
》
Main cause
・
Establishment atmosphere temp. of the hot-air
generator is high.
・
Hot-air that leaked from the outlet flowed
backward to the control panel inside.
・
Influence of the furnace radiation temp. at the
time of the furnace upper part establishment.
《
》
Return method
Please stop operation by pushing STOP switch.
And, please disarm by turning OFF the breaker
(NFB) of this machine after inside temp. of the
hot-air generator dropped.
TEMP. WARN. lamp (Red) is flickered and "SSc" is
flickered to HOT-AIR TEMP., "ALM" to SETTING
TEMP. And, It becomes blow operation condition.
《
》
Main cause
・
Establishment atmosphere temp. of the hot-air
generator is high.
・
Hot-air that leaked from the outlet flowed
backward to the control panel inside.
・
Influence of the furnace radiation temp. at the
time of the furnace upper part establishment.
・
Malfunction of the SSC cooling fan
《
》
Return method
Please disarm by pushing STOP switch after
inside temp. of the hot-air generator dropped.
-11-