  • Page 1 Stylex / Sirocco / Amfora / Vienna...
  • Page 2 Instructions for use Stylex / Sirocco / Amfora / Vienna 6200 4010 / 6200 4015, 6200 4011 / 6200 4016, 6200 4050 / 6200 4055, 6200 5005 / 6200 5010, 6300 4030 / 6300 4035, 6300 4040 / 6300 4045 (Amfora)
  • Page 3 Address ..............Manufacturer Lopital Notes on symbols Read the user instructions before use.
  • Page 4: Table Of Contents

    Side bars .....................40 3.3. Moving upwards / downwards ...............41 3.4. Water drainage (only for Stylex, Sirocco and Amfora with drip tray) ..42 3.5. Changing batteries (only relates to electrical adjustable versions) ..42 3.6. Charging batteries (only relates to electrical adjustable versions) ..43 Safety functions ..................44...
  • Page 5: Introduction

    Comfort is the primary consideration for both the less able person and the carer. Lopital supplies various versions of its shower stretchers and dressing tables. The range includes stretchers / dressing tables that are secured to a wall, mobile shower stretchers / dressing tables and shower stretchers / dressing tables that are non-mobile.
  • Page 6: Safety

    • 6100 2401 – Wall mounted right and height adjustable • 6100 2402 – Wall mounted left and fixed height • 6100 2403 – Wall mounted right and fixed height The Stylex is available in the following versions: • 6100 3070 – Standard stainless steel 1.2. Safety A failure to comply with the following safety points and the further definitions in this user manual could lead to hazardous situations.
  • Page 7 Electric adjustable: • The use of components (ladders, cables, actuators, batteries, etc.) that have not been supplied by Lopital may result in increased emissions or decreased immunity of the shower stretcher / dressing table. • Charge batteries in a well-ventilated, dry space.
  • Page 8: Warranty

    1.3. Warranty Lopital products are guaranteed for 2 years with respect to construction and / or material faults. In the event of varying warranty terms, the exact period will be indicated on your invoice;...
  • Page 9: Use

    2. Use 2.1. First use Before you use the shower stretcher / dressing table, you must check to ensure the following components are present. These components can be replaced by authorised individuals in the event of damage. These components are the applied parts of the shower stretcher / dressing table.
  • Page 10 Bed cushion (2-part) Pedal Pump Charging point Wall mount Mattress Side-bars Battery Outlet hose | Instructions for use | Shower stretcher / Dressing table...
  • Page 11: Working With The Shower Stretcher / Dressing Table

    2.2. Working with the shower stretcher / dressing table Step 1 (only on mobile variants) Always apply the brake on the shower stretcher / dressing table when transferring patients. (See paragraph 3.1. wheel blocking). Transfer to bed Step 2 Place the shower stretcher / dressing table alongside the bed with the head-end aligned with the head-side of the less able person.
  • Page 12: Operation

    • The shower stretcher / dressing table is equipped with steel, hinged side bars. The side bars are made of stainless steel on the Stylex. • The side-bar is equipped with safeguards so that the less able person cannot raise the side-bars himself.
  • Page 13: Moving Upwards / Downwards

    3.3. Moving upwards / downwards Electric adjustable versions Moving upwards • If the less able person is lying on the shower stretcher / dressing table, first put the brake on the wheels (if it is a mobile stretcher / dressing table) and then move the stretcher upwards.
  • Page 14: Water Drainage (Only For Stylex, Sirocco And Amfora With Drip Tray)

    Figure 8: Moving downwards 3.4. Water drainage (Only for Stylex, Sirocco and Amfora with drip tray) • Water is drained away from the shower stretcher via a drainage hose. • Take the hose off the hook and direct it to a drainage point that is as low as possible.
  • Page 15: Charging Batteries (Only Relates To Electrical Adjustable Versions)

    • In order to remove the battery, use one hand to unlock the catch (1) on the battery, then slide the battery to the right (2). (See figure 9). • To install the fully charged battery, it must first be positioned next to the electronic housing and then clicked into the holder.
  • Page 16: Safety Functions

    4. Safety functions 4.1. Emergency stop button (only relates to electrical adjustable versions) In the centre of the undercarriage, there is an emergency stop button. Operate this button in an emergency; if the upward or downward movement must be stopped immediately. After the emergency stop has been pressed, all electrical operation will cease to function.
  • Page 17: Cleaning And Maintenance

    5. Cleaning and maintenance The shower stretcher / dressing table must be cleaned after every use, with water and regular household cleaning agents. Remove excess soap residues. Do not use any abrasive or other aggressive cleaning products (e.g. chlorine bleach). Practical experience has shown that regular household cleaning agents with limited alcohol content (max.
  • Page 18: Storage And Transport

    / dressing table must be maintained in line with the manufacturer’s instructions. This process will preferably be carried out by Lopital or another authorised body. Lopital offers the option of having the shower stretcher / dressing table thoroughly inspected and serviced once a year via Periodic Preventative Maintenance.
  • Page 19: Removal Of Parts

    7. Removal of parts All parts that are replaced or removed can be sent back to Lopital BV. You may also offer the parts to the engineer for destruction. We will ensure that all parts are processed in an environmentally-friendly manner.
  • Page 20: Drive

    6100 2401 80 kg 176.4 lbs 6100 2402 40 kg 88.2 lbs 6100 2403 40 kg 88.2 lbs Stylex 6100 3070 50 kg 110.2 lbs Maximum load 135 kg / 297.6 lbs 8.2. Drive (Electric variants) High-low drive Actuator 24 V DC Control box 24 VDC, max.
  • Page 21: Dimensions

    78.7 x 31.9 inch 6100 2403 200 x 81 cm 78.7 x 31.9 inch Stylex (l x w x h) 6100 3070 – 194 x 72,5 x 75 tot 118 cm 764 x 28.3 x 29.5 tot 46.5 inch Water drainage hose Internal Ø...
  • Page 22 | Instructions for use | Shower stretcher / Dressing table...
  • Page 23 Shower stretcher / Dressing table | Instructions for use |...
  • Page 24: Checklist For Technical Problems

    / dressing table is hard to move Connection between pump Tighten screws on connector and pedal has become discon- nected Contact Lopital Pump leaking or broken Turn emergency button 90 degrees to the right Shower stretcher / dressing table Emergency stop button used...
  • Page 25: Relationship With Other Supports

    10. Relationship with other supports EasySlide The EasySlide is the ideal device for transferring from bed to shower stretcher / dressing table and vice versa. The physical burden and time required when using the EasySlide is minimal. The EasySlide is suitable for most bed and chair transfers from and to the shower stretcher / dressing table.
  • Page 26: Electromagnetic Compatibility

    11. Electromagnetic compatibility (For electric variants) Guidance and Manufacturer’s declaration-electromagnetic emissions The shower stretcher / dressing table is intended for use in the electromagnetic environment specified below. The customer or the user of the shower stretcher / dressing table should assure that it is used in the following environment: Emissions Test Compliance Electromagnetic Environment - guidance...
  • Page 27 Guidance and Manufacturer’s declaration-electromagnetic immunity The shower stretcher / dressing table is intended for use in the electromagnetic environment specified below. The customer or the user of the shower stretcher / dressing table should assure that it is used in the following environment: Immunity Test IEC 60601-1-2 Test Compliance Level...
  • Page 28 Guidance and Manufacturer’s declaration-electromagnetic immunity The shower stretcher / dressing table is intended for use in the electromagnetic environment specified below. The customer or the user of the shower stretcher / dressing table should assure that it is used in the following environment: Immunity Test IEC 60601-1-2 Test Compliance Level...
  • Page 29 Recommended separation distance between portable and mobile RF communications equipment and the shower stretcher / dressing table The shower stretcher / dressing table is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the shower stretcher / dressing table can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the shower stretcher / dressing table as recommended below, according to the maximum output power of the communications equipment.
  • Page 30 User4010 05-2017...