C A U T I O N
Confi rm that fi eld-supplied electrical components
(main switch fuse, fuse-free breaker, earth leakage
breakers, wires, conduit connectors and wire
terminals) have been properly selected ac- cording
to the electrical data given in the Technical Catalog of
the unit and ensure that the components comply with
national and local codes.
N O T E
For more reference check Troubleshooting
chapter on Opera- tion Part.
For twin, triple and quad check the indoor unit
outlet air tem- perature at test run. If the temperature
difference is large (aprox. 10 deg. or more (cooling)
20 deg. or more (heating) recheck the refrigerant
piping, Installation may have some problem.
In the case of anual cooling optional function,
cut JP1 out and set the DSW6-1 to OFF. (Individual
control is not available when anual cooling is
selected).