Built-in Cycle Counter
The Electronic Control Board includes an internal non-resettable cycle counter.
and the value is stored in the internal memory of the control board, providing valuable data for maintenance
scheduling.
1. Verify if the close limit switch is activated and if the close LED is ON.
2. Set select switch on E.
3. Wait until all 3 Indicator LEDs have turned OFF:
GREEN (D2), RED (D3) and ORANGE (D4).
4. Press the "Open" button to activate the Cycle Counter Display
Sequence. The 3 Indicator LEDs will FLASH in order to display the #
of cycles as follows:
ORANGE LED (D4) a # of 100K cycles
RED LED (D3) a # of 10K cycles
GREEN LED (D2) a # of 1K cycles
Ex: 205 000 cycles or 205 999 cycles will be displayed the same:
ORANGE LED (D4) a will FLASH
RED LED (D3) a
GREEN LED (D2) a
Note: Quantities under 1000 cycles are not displayed.
5. During the Cycle Counter Display Sequence, pressing the "Stop"
button will stop the 3 Indicator LEDs from flashing. Pressing the
"Open" button once again, will commence the Counter's Display
Sequence.
6. Set select switch run mode (0, 1, 2, 3, 4 or 5).
Refer to Run Mode Settings section, p. 24 for mode descriptions.
Mid Stop (MD STP)
• The Mid-Stop position must always be programmed/adjusted so that there is a minimum gap of 12"
between the top of the tallest vehicle and the bottom edge of the door.
Mid-Stop, when activated, will allow the door to stop at a predetermined position when an open signal is given from
the fully closed position. The Radio control or Close push-button will close the door from the mid-stop position. The
door will open fully from mid-stop position if the Open button is activated.
Mid-Stop Activation
1. Verify if the close limit switch is activated and
if the close LED is ON.
2. Set select switch on C = MdStP.
3. Press the "Open" button. While door is
moving press "Stop" button at desired (mid-
stop) position.
4. Set select switch on run mode (0, 1, 4, or 5).
For technical support, please call 1-800-361-2260 or visit
Cycle Counter Display
2
times (
0
will FLASH
times (2
5
will FLASH
times (20
NOTICE
26
2
00 000);
0
0 000);
5
000)
Select Switch
1. Verify if the close limit switch is
2. Set select switch on C = MdStP.
3. Press the "Stop", "Close" and "Open"
4. Set select switch on run mode
www.manaras.com
Each complete door cycle is counted
Select Switch
Indicator LEDs
Cycle Counter Display Sequence
D2 (GREEN LED):
# of 100K cycles
D3 (RED LED):
# of 10K cycles
D4 (ORANGE LED):
# of 1K cycles
Mid-Stop Deactivation
activated and if the close LED is ON.
buttons consecutively.
(0, 1, 2, 3, 4 or 5).