Download Print this page

ProDevice ASM 120 Instruction Manual page 13

Degausser
Hide thumbs Also See for ASM 120:

Advertisement

Instruction manual
ASM120
Instruction manual
Despite the complete degaussing of the medium after the first cycle, it is
recommended to turn the cassette by 90° and degauss it again to "smooth"
the remains of any magnetic fluxes.
Using ASM120 degausser with a PC
The device is adapted for use with a PC with software to enable configuration
and checking degausser operating parameters.
ASM120 has a RJ45 Ethernet port hidden in the rear panel of housing. The
RESET button is located next to the port used for changing the settings of
network address to a standard address in case of loss of device's network
address settings.
To change network address to standard address, press and hold RESET for
approx. 5 s after turning the device on with the main power switch. Change of
the network address to default value is shown with applicable message on
the display.
Communication between computer and the device is possible only
directly after turning on the device with main switch before the first
change of the position of the drawer. Communication with PC is locked
after changing the position of the drawer.
NOTE Detailed description of work of ASM 120 with PC and information
on the use of PPMS are given in a separate manual.