3.
Close the drawer (3) after placing a storage medium for degaussing in
the drawer.
ATTENTION! During degaussing cycle, you could place only one
piece of media in the drawer (no matter what is the media size)!
4.
Approx. 30 s loading cycle starts after closing the drawer. The cycle
progress is shown on the LCD.
5.
Degaussing begins after the completion of loading cycle. A message
about successful or failed degaussing cycle is shown on the LCD.
6.
Opening the drawer and removing the medium is the end of the cycle.
7.
Placing another storage medium inside and closing the drawer starts a
new cycle.
NOTE Opening the drawer during the cycle interrupts it and the user is
informed about it with a message on the display.
Press the power button after the completion of the cycle to turn off the device
correctly (with the drawer still closed/open) or during 3 seconds after closing
the drawer (before starting next degaussing cycle).
NOTE The PPMS technology (programming the degausser to a selected
number of erase cycles) may result in an automatic lock of the device.
The lock will be activated after degaussing the predefined number of
storage media. To unlock the device and continue operation, contact
manufacturer or distributor.
Degaussing instructions for DLT media
ASM120 lets the user erase DLT storage media in plastic protective
cartridges.
Note DLT cartridges can be reused after degaussing!