Assembling the remaining thread monitor
9. Roll up the remaining thread monitor cables that are too long and fix
Fig. 5: Connecting the remaining thread monitor on Classic machines (4)
(8) - Y-connection
(9) - Hoses
10. Assemble the valve (10).
11. Disassemble the valve unit.
12. Screw the valve (10) to the valve rail.
13. Assemble the valve unit.
14. Connect the hoses (9) of the remaining thread monitor to the valve.
15. Assemble hoses and cables with clips to the oil return line and to the
16. Connect the magnet valve electrically to the valve circuit board.
Additional Instructions 867/867-M PREMIUM - 00.0 - 07/2018
them to the base plate of the remaining thread monitor control with
cable ties.
Ensure that the sealing washer is in the correct position when doing this.
With right AND left remaining thread monitor: Connect hoses (9)
to Y-connection (8).
knee lever shaft.
• X22, PIN 1/7/8 (+) and PIN4 (FL)
OR
• X22, PIN 1/7/8 (+) and PIN2 (FA)
(10) - Valve
X22