1.
Remove the pop-up stopper (E) and pop-up flange (F) from the pop-up
assembly.
2.
Apply adequate amount of plumbers putty underside of pop-up flange
(F). Then insert pop-up drain assembly from underside of the sink and
secure the pop-up flange (F) from the top.
3.
Rotate the drain body so that horizontal rod hole faces back of the fau-
cet.Hold the pop-up assembly in place and tighten the locknut (G).
4.
Remove the excess putty. Connect the trap (H) (check manufacturer's
instructions for installation).
5.
Remove rod nut (I).
6.
Ensure the washers (K) is in place (for brass pop-up only). Insert rod (J).
Tighten the rod nut (I).
7.
Push rod down to open drain. Insert the pop-up stopper (E) carefully.
Test if the pop-up stopper (E) is working properly.
8.
Connect pop-up bracket to the rod using clip (L). Tighten the thumb-
screw (M) to connect pop-up bracket to pop-up lift rod.