INSTRUCTION MANUAL

General

The Hy-Gain AR-40 antenna rotator is designed
to support and rotate large TV antennas, small CB
base antennas, and small Amateur antennas. The
AR-40 is rated to rotate antennas with up to 1.5
sq. ft. of wind area when mast mounted or 3.0 sq.
ft. when mounted inside a tower.
The AR-40 rotator unit must be wired to the con-
trol unit with a 5-wire cable. Number 22 gauge 5
conductor cable will allow normal operation for
cable lengths of up to 75 feet (22.86 m). For
longer runs, use a heavier gauge wire.
The control unit must be placed inside the house
or other protected location. The maximum voltage
produced by the control unit is 18 VAC.

Pre-Installation Check and Calibration

Before mounting the rotator unit on your mast or
tower, check the operation with the control unit
and cable. Strip all conductors at both ends of the
cable and attach to the terminals. Connect
terminal 1 to terminal 1, etc. On the control box,
simply insert the bare wire between the nut and
the terminal and tighten the screw. Do not wrap
the wire around the screw!
Plug the control unit line cord into a convenient
wall outlet. Turn the direction control knob to
"N". Momentarily press down on the start button.
The rotator will start to turn and the indicator light
will come on. When the rotator reaches "N", it
will automatically stop and the light will go off.
Figure I

Control Unit-Top View with Cover

AR-40 / AR-40X
Antenna Rotator

Advertisement

loading

Summary of Contents for Hy-Gain AR-40

  • Page 1 Amateur antennas. The cable and attach to the terminals. Connect AR-40 is rated to rotate antennas with up to 1.5 terminal 1 to terminal 1, etc. On the control box, sq. ft. of wind area when mast mounted or 3.0 sq.
  • Page 2 Leave the rotator in the full clockwise (South) Turn the knob COUNTERCLOCKWISE to "S" position for installation. Disconnect the power and press the start button. If the rotator unit stops plug and remove the 5-wire cable from the before the South position and the indicator light control unit.
  • Page 3 Installation on Mast Mount the rotator to the lower mast support and then attach the support to the mast. (See Figure 3) Attach one end of the 5-wire cable to the rotator unit terminals. the cover and grommet must be slipped over the cable prior to attaching it.
  • Page 4 Top of Tower Mounting Top of tower installation is similar to mast mount- ing. (See Figure 5) Spacer washers must be used between the rotator bottom and tower plate. This allows the rotator housing bolt heads to clear the tower plate. The tower plate must be drilled in four (4) places using the template provided with this manual, unless already pre-drilled.
  • Page 5 The price includes rebuilding the unit, replacing Starkville, Mississippi 39759 USA all defective and/or worn parts, and return freight charges. Hy-Gain reserves the right to change prices at its option. when returning items for re- pair, a check or money order for the repair charges must be included.
  • Page 6 This information is believed correct, but no warranty is given or implied and no liability is assumed by Hy-Gain as to its accuracy or completeness. Changes maybe made from time to time so the user should verify all factors tht may be critical. This information is not to be construed as to authorizing...