Important NOTICES for operation. Changing the deashing interval ....35 CAUTION: Failure to observe these notices can result in property damage. STOP: Failure to observe these notices can result in personal injury. www.eta.co.at Subject to change due to technical improvements...
Page 3
Preface Dear customer, We are delighted to count you among our customers. To ensure satisfactory operation of your new boiler, you need to know how to operate, clean and Please read this manual maintain it. This manual contains information and advice on much more than just the boiler itself.
Cleaning and maintenance are required as propellants, or ammonia from cleaning agents, to specifi ed in the user manual. prevent corrosion of the boiler and chimney. www.eta.co.at Subject to change due to technical improvements...
Page 5
For repair of defects carried out by the customer or by third parties, ETA only bears the costs or remains obligated by warranty if this work was approved in advance by the customer service of ETA Heiztechnik GmbH.
Open all the radiator valves and turn the radiator automatically switch back to normal mode after thermostats to maximum. 30 minutes. Finally, switch the boiler back on using the on/off button ( button lights up green). www.eta.co.at Subject to change due to technical improvements...
Operation with external air supply Heating appliances, cooker hoods and Air supply via blinds central vacuum cleaners need air supply The slats in the blinds open due to the pressure difference and admit air into the room. This To keep ventilation heat losses under control, solution is safe and simple but can be an airtightness (blower door test) is a crucial issue in unpleasant source of leaks in rooms with...
Technical requirements for the flue can be found in the installation instructions (a separate document from this user manual). www.eta.co.at Subject to change due to technical improvements...
Maintenance Every 2,200 kg Maintenance every Warning message "Water pressure too low" 2,200 kg of pellets For "Water pressure too low" (warning at 1.5 bar and shutdown at 1.0 bar), fill the cold After every 2,200 kg of pellets or at least once heating system to approx.
Reattach the ash box to the boiler and secure it with the side latches. In the "Boiler" overview, restart the boiler with the on/off button . The boiler automatically starts heating if required. Ash box www.eta.co.at Subject to change due to technical improvements...
Maintenance Overview of activities "Empty ash box" reminder The ash box should be emptied regularly. As such, the factory settings contain a pellet consumption A settings screen opens: level at which a reminder to empty the ash box appears. If the ash box is only part full after this time, the value in the "Empty ashbin after"...
Before starting this maintenance, stop the current heating operation. In the "Boiler" overview, press the on/off button Then let the boiler cool off for at least 2 hours before starting the maintenance. www.eta.co.at Subject to change due to technical improvements...
Maintenance After 6,000 kg Clean the combustion chamber and flue Clean with the poker collection box Use the poker (stored behind the front panel above the ash box) to remove the combustion To gain access to the combustion chamber and the chamber cover from the combustion chamber and flue collection box in front of the fan, the panel scrape the ash from the walls.
Replace the panel on the top of the boiler. Inspect seal on heat exchanger cover Clean the heat exchanger cover and check the integrity of the seal. Screw The maintenance is now completed. www.eta.co.at Subject to change due to technical improvements...
Maintenance Expert maintenance after 10,000 kg Maintenance after 10,000 kg If the valve still cannot be closed tightly after being rinsed several times, it must be cleaned or by an expert replaced. When 10,000 kg of pellets have been used, a Buffer storage tanks with solar charging must also screen message demands maintenance by an be equipped with a safety valve;...
If tar deposits are present, contact our customer service. Calibrate lambda probe If no emission measurement is possible, the lambda probe must be calibrated with the heat exchanger cover open; see next page. www.eta.co.at Subject to change due to technical improvements...
Page 19
Maintenance Expert maintenance after 10,000 kg Automatic calibration of the lambda probe Starting the "Additional calibration" function The boiler's built-in lambda probe checks the In the submenu, scroll down and double-tap on residual oxygen content of the fl ue gas and uses the [Additional calibration] line.
Page 20
For a correct measurement, the value for the [Measuring orifice] parameter must be 0 Pa. If a deviating value is shown, the measurement must be calibrated. www.eta.co.at Subject to change due to technical improvements...
Page 21
Maintenance Expert maintenance after 10,000 kg Safety valve Firebed level sensor Drive chains for Drive chain for stoker cleaner and grate Fill level sensor Hoses for differential pressure transmitter Operation PC 20 to 32 kW 2011-12...
For uninsulated piping systems, the measurement area must be insulated with mineral wool at least 20 mm thick over a length of at least 20 cm of pipe. www.eta.co.at Subject to change due to technical improvements...
Softened heating water, Safety valve Initial fi ll-up with softened water and to keep the lime content to a minimum during water additions. enough shut-off valves All relevant standards demand softened water for heating systems with larger water volumes. Protection against corrosion For the boiler a value of 20,000 lt°dH for system volume in litres multiplied by the hardness To limit corrosion with softened water, the...
• For air heating systems or also individual heating fans that are started without warm-up time for the boiler. • For integration of a solar heating system with a low-temperature heating system www.eta.co.at Subject to change due to technical improvements...
Overtemperature, safety temperature limiter Pump safety run, Automatic heat dissipation at overtemperature If the boiler temperature exceeds 90°C (factory setting) for any reason, the pump safety run will start. All heating pumps and boiler pumps that are connected to the boiler control are switched on to dissipate heat from the boiler.
Error messages for the selected function closes the screen without saving the block changes. saves changes and closes the screen. Toolbox for experts INFO Help www.eta.co.at Subject to change due to technical improvements...
Changing the language Changing the language It is possible to change the language on the screen. Selecting a language Switching to the toolbox Select the language you require and Press the button to switch to the toolbox. confi rm by pressing the button.
HC has now been renamed "FLOOR". The names of all the function blocks can be changed at any time. A small screen appears for this function block. Tap the [Change Name] button. An on-screen keyboard appears. www.eta.co.at Subject to change due to technical improvements...
Error, Alarm, Warning, Message Message Displaying an error Press the button to go to the list of errors for This icon in the function block buttons indicates a the current function block. message. Messages do not interrupt operation of the If an alarm or warning occurs in any function boiler, nor must they be confi rmed.
Read through the corresponding section of the user manual before making changes. If the explanation of the relevant function given in the manual is not suffi cient for your purposes, confer with an expert. www.eta.co.at Subject to change due to technical improvements...
Boiler Overview, buttons, functions "Boiler" overview Fill-up time Press to open the "Boiler" overview screen. This button can be used to set the latest time at which the boiler's storage tank is completely fi lled The overview screen shows you at a glance what up.
Failure start up the boiler. A malfunction has occurred, preventing the boiler from heating. The cause can be found in the list of error messages. www.eta.co.at Subject to change due to technical improvements...
Boiler Changing the fill-up time Defi ning the fi ll-up time "Fill up pellets" function It is possible to adjust the latest time for fi lling The "Fill up pellets" function can be used to fi ll up up the storage tank before night time, in order to the boiler's storage tank regardless of the current prevent disturbances.
The duration of the idletime can now be changed. Press to confi rm. Enter the new time and press to save Press the button to return to the overview. changes. Press the button to return to the overview. www.eta.co.at Subject to change due to technical improvements...
Ash removal is performed at a point between these two limits. The deashing interval should only be altered after consultation with an expert or ETA Customer Service. Deashing interval factory settings The parameters are set at the factory to:...
The current target fl ow temperature for the heating The boiler has a separate on/off button. circuit is only displayed if the heating circuit is Green = Heating circuit on switched on and in operation. Red = Heating circuit off www.eta.co.at Subject to change due to technical improvements...
Page 37
Heating circuit Overview, buttons, functions Outdoor -13°C Current outside temperature Come The current outside temperature is measured by the built-in outside temperature sensor. This function is only available in "Auto" mode. Regardless of the current time slot, pressing the button (when you come home) switches the heating circuit to "Day"...
If the unit has a built-in room sensor, the boiler (overheating protection). temperature is regulated to the highest room temperature set for the time slot. The switch can be in either the "Auto" or the "Day" position. www.eta.co.at Subject to change due to technical improvements...
Page 39
Heating circuit Operating modes On Screed Off Hot water The heating circuit is in operation; the screed The heating circuit is switched off because the hot drying program is being run. water is currently being heated. Off Enable temp. Off Room night The heating circuit is still switched off because the The heating circuit is switched off and outside the boiler is not yet able to supply suffi cient heat.
In the overview for the selected heating circuit, tap the timer. The screen for setting the timer opens. Room sensor only Press to save the new settings. Use the same method to adjust the other time slots. www.eta.co.at Subject to change due to technical improvements...
Page 41
Heating circuit Heating time slots Copying time slots to other days of the week "Holiday" function Once the time slots have been adjusted, they can With this function, the button can be used to also be adopted for other days of the week. switch the heating circuit to constant "Night"...
Underfl oor heating is usually limited to 45°C, while the heating circuit. For information on these radiators with metal pipes can take temperatures parameters and their factory settings, see up to 85°C. page 44. page 82. www.eta.co.at Subject to change due to technical improvements...
Heating circuit „Day and Night Heating threshold“ The parameter "Day Heating threshold" The parameter "Night Heating threshold" With the "Day Heating threshold" parameter, an If the heating circuit is in "Night" mode, an outside outside temperature is set which, when exceeded, temperature is set which, when exceeded, will will result in the heating circuit being switched to result in the heating circuit being switched off.
Outside temperature (°C) Outside temperature (°C) Do not change the fl ow temperature "Flow at +10°C" in winter. Do not change the fl ow temperature "Flow at -10°C" during the transition period. www.eta.co.at Subject to change due to technical improvements...
Page 45
Heating circuit Adjusting the heating curve Adjusting the heating curve for outside Adjusting the heating curve for outside temperatures above 0°C -> Changing temperatures below 0°C -> Changing "Flow at +10°C" "Flow at -10°C" If the heating circuit is always too cold or too warm If the heating circuit is always too cold or too warm in the transition period, the fl ow temperature in winter, the fl ow temperature "Flow at -10°C"...
Enter the new enable temperature for this heating circuit. Press to save the new value. The text menu for the selected heating circuit is displayed. Press to return to the heating circuit overview. www.eta.co.at Subject to change due to technical improvements...
Heating circuit Adjusting the „Set-back“ The parameter "Set-back" Changing the parameter "Set-back" If the unit does not have a room sensor, the Press to open the text menu for the selected parameter "Set-back" is used to adjust the night heating circuit. mode.
"heating circuit" function block must be set to 21°C. The fi xed temperature sensor temperature in the room sensor must be also be adjusted to is switched off 21°C, using potentiometer P3 (7). www.eta.co.at Subject to change due to technical improvements...
Pellet store Overview, buttons, functions "Pellet store" overview Enter stock Press to open the "Store" overview screen. This button can be used to enter the new stock quantity after a delivery of pellets. This function block is used to control pellet feeding by discharge screw or a single suction head.
There is a problem with the discharge screw. This has been detected due to overcurrent, warming or insuffi cient current consumption. Enter the new stock quantity and press to save. The display returns to the overview. www.eta.co.at Subject to change due to technical improvements...
Store with switching unit Overview, buttons, functions "Pellet store" overview Enter stock Press to open the "Store with switching unit" overview screen. This button can be used to enter the new stock quantity after a delivery of pellets. In this function block, a pellet conveying system is controlled using a switching unit and 2 or 3 suction heads.
Page 52
All suction heads have been locked. Conveying is thereby prevented. At least one suction head must The pellet conveying system is not in operation. be enabled. There is no demand from the boiler. www.eta.co.at Subject to change due to technical improvements...
Store with switching unit Locking and changing heads Locking/enabling a suction head If the store above a suction head is empty or if a Switching unit switching suction head suction head is damaged, it can be locked. The Once the maximum fi ll up level (= parameter switching unit will then no longer select this "Switching at") has been reached, the switching suction head.
A screen for adjustments opens. Enter the new stock quantity and press to save. The display returns to the overview. Enter the new value and press to save. Press to return to the overview. www.eta.co.at Subject to change due to technical improvements...
Internet connection In order to establish an Internet connection to The ETA boiler's touch screen is connected to the your boiler, the touch screen must be connected Internet. Once you have registered your touch to the Internet. To do this, the house must have a screen, you can log in to the ETA homepage broadband Internet connection.
To re-activate remote control, tap the icon on the touch screen and select "On" in the window that appears. symbol appears while the connection is being established. www.eta.co.at Subject to change due to technical improvements...
"Only View" mode can only be selected when If the "Only View” mode is selected, remote control is "On". using remote control, the ETA customer service is able to monitor and provide assistance, for example, but is unable to make changes. "Off" mode, remote control is switched off.
In particular, you should avoid switching the boiler on via remote control if an error message is present. www.eta.co.at Subject to change due to technical improvements...
Remote Control Logging out Example: Switching on the boiler Logging out of remote control Press the On/Off button to switch on the Once you have fi nished using remote control, press boiler. the [Logout] button on the homepage. The display returns to the start page. Closing the touch screen display Press [Back] to close the touch screen display.
If a touch screen is added at a later date, the current login data (username and current password) are always required. In the user menu, tap [Edit my account]. The screen will display your current details. www.eta.co.at Subject to change due to technical improvements...
Efficient and low-emission operation Dear customer, Your new boiler is labelled with the "Blue Angel" to indicate its environmental friendliness. With this in mind, please note the following for effi cient and low-emission operation of your heating system: 1. The installation and adjustment of the heating system must be performed only by qualifi ed and trained personnel.
Then you and our customer service will have an overview of the work performed on the system. Service / maintenance / cleaning Date Performed by Work performed / parts replaced www.eta.co.at Subject to change due to technical improvements...
Page 63
Service and maintenance records Service / maintenance / cleaning Date Performed by Work performed / parts replaced Operation PC 20 to 32 kW 2011-12...
Area unsafe for children! Smoking, naked flame or any other ignition sources are prohibited! Ensure that the ETA pellet boiler is in automatic mode while store is being filled! Switch main power supply to OFF before entering the pellet storage area!