Cleaning; Safety Inspection; Disposal - ebm-papst G1G144-AF49-01 Operating Instructions Manual

Table of Contents

Advertisement

G1G144-AF49-01
Impeller not
Imbalance in rotating
running smoothly
parts
Motor not turning
Mechanical blockage
Line voltage faulty
Faulty connection
Motor/electronics
Deficient cooling
overtemperature
Ambient temperature
too high
Impermissible point of
operation
Deflagration
Leakage of the air/
gas mixture being
conveyed
In the event of further malfunctions, contact ebm-papst.

6.1 Cleaning

NOTE
The device does not need to be cleaned.

6.2 Safety inspection

NOTE
High-voltage test
The integrated EMC filter has Y capacitors. The tripping current
is exceeded when AC testing voltage is applied.
→ Test the device with DC voltage when you perform the
legally required high-voltage test. The voltage to be used
corresponds to the peak value of the AC voltage required by
the standard.
What to check
How to check
Contact
Visual inspection At least every
protection
cover for
intactness or
damage
Item no. 51263-5-9970 · ENU · Change 261204 · Approved 2022-06-10 · Page 10 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Clean the device;
replace it if imbalance
persists after cleaning.
Make sure no
weight clips are
removed during
cleaning.
Switch off, isolate
from supply and
remove mechanical
blockage.
Check line voltage,
restore power
supply, apply control
signal.
Isolate from supply,
correct connection;
see connection
diagram.
Improve cooling. Let
the device cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Reduce the ambient
temperature.
Reset by reducing
control input to 0.
Correct the operating
point. Let the device
cool down.
Check for leaks;
replace blower if not
properly sealed
How often
What action?
Repair or
6 months
replacement of
device
Device for
Visual inspection At least every
damage to
blades and
housing
Fastening the
Visual inspection At least every
cables
Fastening the
Visual inspection At least every
protective earth
terminal
Insulation of
Visual inspection At least every
cables for
damage
Abnormal
acoustic
bearing noise

6.3 Disposal

For ebm-papst, environmental protection and resource preservation are
top priority corporate goals.
ebm-papst operates an environmental management system which is
certified in accordance with ISO 14001 and rigorously implemented
around the world on the basis of German standards.
Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.
The following section contains recommendations for ecological disposal
of the product and its components.
6.3.1 Country-specific legal requirements
NOTE
Country-specific legal requirements
Always observe the applicable country-specific legal
regulations with regard to the disposal of products or waste
occurring in the various phases of the life cycle. The
corresponding disposal standards are also to be heeded.
6.3.2 Disassembly
Disassembly of the product must be performed or supervised by
qualified personnel with the appropriate technical knowledge.
The product is to be disassembled into suitable components for disposal
employing standard procedures for motors.
WARNING
Heavy parts of the product may drop off. Some of the
product components are heavy. These components
could drop off during disassembly.
This can result in fatal or serious injury and material damage.
→ Secure components before unfastening to stop them falling.
6.3.3 Component disposal
The products are mostly made of steel, copper, aluminum and plastic.
Metallic materials are generally considered to be fully recyclable.
Separate the components for recycling into the following categories:
Steel and iron
Aluminum
Non-ferrous metal, e.g. motor windings
Plastics, particularly with brominated flame retardants, in accordance
with marking
Insulating materials
Cables and wires
Electronic scrap, e.g. circuit boards
Replacement of
6 months
device
Fasten
6 months
Fasten
6 months
Replace cables
6 months
At least every
Replace device
6 months

Advertisement

Table of Contents
loading

Table of Contents