R3G280-RR10-P1
Faulty connection
Overtemperature of
Insufficient cooling
electronics/motor
Thermal overload
protector responded
Ambient temperature
too high
Unacceptable
operating point
If you have any other problems, contact ebm-papst.

5.1 Cleaning

To ensure a long service life, the fans have to be regularly checked for
proper operation and degree of soiling. The frequency of the checks is to
be adapted to the occurrence of soiling.
; Dirt deposits on the motor housing could lead to overheating of the
motor.
; Dirt on the impeller can cause vibration which would shorten the
service life of the fan.
; Severe vibration could destroy the fan.
; In such cases immediately switch off and clean the fan.
; The preferred method of cleaning is dry cleaning, e.g. using
compressed air.
; Use is never to be made of corrosive cleaning agents!
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not use a high-pressure cleaner to clean the device.# Do
not use any acid, alkali or solvent-based cleaning agents.
→ Do not use any pointed or sharp-edged objects for cleaning
; Completely remove any cleaning agents used.
; Immediately switch off and replace the device if severe corrosion is
apparent at load-bearing or rotating parts.
; Repairs to load-bearing or rotating parts are not permissible!
; Operate the fan for 2 hours at maximum speed to permit the
evaporation of any water which may have ingressed.
; If cleaning does not eliminate vibration, the fan may have to be re-
balanced. In such cases please contact ebm-papst.
; The fan is provided with maintenance-free ball bearings. The lifetime
lubrication of the ball bearings is designed for a service life of 40,000
hours.
Item no. 53890-5-9970 · ENG · Revision 257061 · Release 2023-02-03 · Page 10 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
De-energise, correct
; Please contact ebm-papst if bearing replacement is required after this
connection, see
connection diagram.
; Adapt the maintenance intervals to the dust pollution occurring.
Improve cooling. Let

5.2 Safety test

the device cool down.
To reset the error
What has to
message, switch off
be tested?
the mains supply
Check the
voltage for a min. of
protective
25 s and switch it on
casing against
again.
accidental
Allow motor to cool
contact for
off, locate and rectify
damage and to
cause of error, if
ensure that it is
necessary cancel
intact
restart lock-out
Check the
Reduce the ambient
device for
temperature.
damage to
Reset by reducing
blades and
control input to 0.
housing
Correct the operating
Mounting the
point. Let the device
connection lines
cool down.
Mounting of
protective earth
connection
Check the
insulation of the
wires for damage
Impeller for
wear/deposits/
corrosion and
damage
Condensate
discharge holes
for clogging, as
necessary
Abnormal
bearing noise
Vibration test

5.3 Disposal

For ebm-papst, environmental protection and resource preservation are
top priority corporate goals.
ebm-papst operates an environmental management system which is
certified in accordance with ISO 14001 and rigorously implemented
around the world on the basis of German standards.
Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.
The following section contains recommendations for ecological disposal
of the product and its components.
period.
How to test?
Frequency
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
acoustic
At least every
6 months
Vibration tester,
Recommended
acceleration or
every 6 months
deceleration
measurement
Which
measure?
Repair or
replacement of
the device
Replacement of
the device
Fasten
Fasten
Replace wires
Clean impeller
or replace device
Open bore holes
Replace device
Clean impeller
or replace device

Advertisement

Table of Contents
loading

Table of Contents