Download Print this page

Candy CHK64C Instruction Manual page 7

Advertisement

The ceramic hob is manufactured to work with three-
phase alternating current (400V3N~50Hz).The voltage
rating of the ceramic hob heating elements is 230V.
Adapting the ceramic hob to operate with one-phase
current is possible by appropriate bridging in the
connection box according to the connection diagram
below. The connection diagram is also found on the
cover of the connection box. Remember that the
connection wire should match the connection type and the power rating of the ceramic
hob.
The connection cable must be secured in a strain-relief clamp.
Warning!
Remember to connect the safety circuit to the connection box terminal marked with
.The electricity supply for the ceramic hob must have a safety switch which
enables the power to be cut off in case of emergency. The distance between the
working contacts of the safety switch must be at least 3mm.
Before connecting the ceramic hob to the power supply it is important to read the
information on the data plate and the connection diagram.
CONNECTION DIAGRAM
Caution! Voltage of heating elements is 230V
Caution! ln the event of any connection
the safety wire must be connected to the
For 230 V earthed one-
1
phase connection, bridges
connect 1-2 terminals, safety
wire to
.
2 For 400/230V earthed two-
phase connection, the safety
wire to
.
L1=R,L2=S,L3=T,N=earth terminal, PE= safety wire terminal
 The cable connections must be in accordance with the diagram located on the
bottom of the hob .
 You should use a good quality screwdriver to carefully, fully tighten ALL of the
terminal screws.
1
2
3
PE terminal
1
2
3
L1
4
PE
N
1
2
3
L2
L1
4
PE
N
7
2
1
Recommended
type of connection
4
lead
H05VV-F 3G2.5
H05VV-F 4G2.5

Hide quick links:

Advertisement

loading