PIM00318A_EN.fm Page 28 Tuesday, October 26, 2010 12:37 PM
Description on parameter settings (Group A)
In this section, set the following parameters by using three digits (first, second and third digits) of each parameter on the control
panel data display.
• "Temperature range warning condition setting" (Use the second and third digits.)
• "Temperature range warning operation setting" (Use the first digit.)
Temperature range warning condition setting
Third digit
Outlet oil temperature [Th2]
(1)
n010
Inlet oil temperature [Th4]
Outlet oil temperature [Th2]
(2)
n012
Inlet oil temperature [Th4]
Room temperature [Th3]
(3)
n014
Machine temperature [Th1]
Outlet oil temperature [Th2]
(4)
n016
Inlet oil temperature [Th4]
Example of parameter settings (for temperature range warning: See page
(1)
When the outlet oil temperature [Th2] (or inlet oil temperature [Th4]) is 15˚C or lower, the compressor stops. (Warning)
When the outlet oil temperature [Th2] (or inlet oil temperature [Th4]) is 35˚C or higher, the compressor stops (FH alarm),
(2)
and the 30W relay output turns ON or OFF.
When the outlet oil temperature [Th2] (or inlet oil temperature [Th4]) is at least 5˚C lower than the room temperature
(3)
[Th3] (or machine temperature [Th1]), the 30W relay output turns ON or OFF.
When the outlet oil temperature [Th2] (or inlet oil temperature [Th4]) is at least 5˚C higher than the room temperature
(4)
[Th3] (or machine temperature [Th1]), the 30W relay output turns ON or OFF.
28
∗ Enter Group B (page
is not activated during setup.
Second digit
2
Fixed value
6
4
2
Fixed value
5
4
3
– Outlet oil temperature [Th2]
2
1
– Inlet oil temperature [Th4]
4
2
– Room temperature [Th3]
3
4
– Machine temperature [Th1]
1
29
) before Group A, so that the temperature range warning
Temperature range warning operation setting
First digit
External output ("Rely 30" output: ON)
Warning
Warning + External output ("Rely 30" output: ON)
External output ("Rely 30" output: ON)
FH alarm
FH alarm + External output ("Rely 30" output: ON)
External output ("Rely 30" output: ON)
Warning
Warning + External output ("Rely 30" output: ON)
External output ("Rely 30" output: ON)
FH alarm
FH alarm + External output ("Rely 30" output: ON)
∗ Example of parameter settings
1
2
3
1
4
5
1
2
3
1
4
5
27
.)
262
n010
(462)
255
n012
(455)
321
n014
(141)
231
n016
(411)