Advisor Advanced events
Table 40: Advisor Advanced events
Group
Event
Zone
ACTIVE
TAMPER
AM
BATTFAULT
FAULT
DIRTY
SVSHORT
SVLONG
INHIBIT
ISOLATE
SOAK
SET
ALARM
RF learned
RF signal accept
Inactive days
Area
FULLSET
PARTSET1
UNSET
ALARM
FSALARM
PSALARM
USALARM
FTCALARM
FIREDOOR
FSFIREDOOR
PSFIREDOOR
USFIREDOOR
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
#
Event description
01
Zone active
02
Zone tamper
03
Zone masking
04
Zone battery fault
05
Zone fault
06
Zone dirty
07
Zone supervision
short
08
Zone supervision
long
09
Zone inhibited
10
Zone isolated
11
Zone in soak test
12
Zone set
13
Zone in alarm
14
Wireless device
programmed
15
Wireless device
found
16
Zone inverted walk
test failed
01
Area full set
02
Area part set 1
03
Area unset
04
Intrusion alarm
05
Alarm during full
set
06
Alarm during part
set
07
Alarm during unset
08
Alarm and FTC
09
Fire door active
10
Fire door during full
set
11
Fire door during
part set
12
Fire door during
unset
Notes
Zone in active state
Zone in tamper state
Zone in anti-mask alarm state
Zone in battery fault state
Zone in fault state
Zone in dirty state
Zone in short supervision state
Zone in short supervision state
Zone state changed to inhibited
Zone state changed to isolated
Soak test is active
Zone in Part set or Full set mode
Zone in alarm. Restores after
alarm acknowledgement.
Active for 3 seconds after a
successful programming
Active for 3 seconds after device
response
Zone has been inactive for
longer than inactive day limit
Area is in full set state
Area is in part set 1 state
Area is in unset state
Area Intrusion alarm is active
Area alarm while in full set
Area alarm while in part set
Area alarm while unset
Area alarm while FTC present
A fire door local alarm is active
A fire door active while area full
set
A fire door active while area part
set
A fire door active while area
unset