CENTRONICS
SERIES 100 PRINTERS
PREVENTIVE MAINTENANCE PROCEDURES
(December 1974)
The following Preventive Maintenance (PM) procedures apply to
the Series 101 and Series 102 printers.
Frequency of PM :
6 months
Time Required:
1.5 hours (approximately)
Cleaning Material:
Medium-bristle cleaning brush,
Twosoft clean cloths,
Liquid Freon
Tools Recommended:
Centronics' Tool Kit No. 63002399-1
Phillips screwdriver
Flat blade screwdriver
Jeweler's eye loupe
Decimal feeler gauges
Oil syringe
Items not available
|
through Centronics
Lubricants Recommended:
. Lightweight oil (choice of three)
Teilus No. 27 (Shell) CDCC Spec. No. 30050005
Teresso No. 43 (Esso) CDCC Spec. No. 30050006
Vacualine No. 1405 (Mobil) CDCC Spec. No. 30050007
Grease — CDCC Spec. No. 30050004
Oil — Anderol No. 465, Spec. No. 30050002 (for bushings
and felt washers only)
Reference Manuals: Series 101 and Series 102 Technical Manual
CENTRONAICS
centronics data computercorp.
hudson, n.h. 03051
telephone (603) 883-O0III
eastern region: (617) 646-8545 (mass.)
central region: (513) 294-0070 (ohio)
western region: (714) 979-6650 (calif.)
centronics data computer (canada) Itd.
mississauga, ontario (416) 625-0770
centronics international corp.
brussels, belgium (02) 762-3572
Specifications subject to change without notice.
©1974 Centronics Data Computer Corp.
(PRINTED in U.S.A, 12-74)
6-2
Rev.