WATANABE WPMZ-3 Series Instruction Manual page 121

Graphical digital panel meter, straingauge/ process
Hide thumbs Also See for WPMZ-3 Series:
Table of Contents

Advertisement

1st Layer
2nd Layer
CompareAL1
CompareAL2
CompareAL3
CompareAL4
2. Output
AnalogOutput
BCD Output
ModbusCom
RS-232C Com
DispSelect
LevelDisp
3.Display
TrendDisp
General
4.System
AlarmLog
Initialize
3rd Layer
(setting items)
Initial values
PatternSelect
Pattern in use
OutputDispValue
None
ActCondition
Always
ComparedMode
LevelJudge
Excess
OnConditions
InTheZone
10000
0
0
10000
Threshold
0
10000
1.00
OnDelay
None
OffDelay
None
OutputMode
Normal
OutputLogic
Negative
OnBgColors
Black
PatternSelect
Pattern in use
OutputRange
0-10V
OutputDispValue
None
0
OutputScale
10000
PatternSelect
Pattern in use
OutputDispValue
None
DataSignalLogic
Negative
SyncSignalLogic
Negative
SlaveAddress
1
Baudrate
19200bps
Parity
Even
Protocol
Modbus-RTU
Baudrate
19200bps
Parity
Even
DataLength
7bit
Stopbit
1bit
Delimiter
CR LF
PatternSelect
Pattern in use
1ch product
MeasureSelect
Ach, Ach + Comp
Level, Trend
LevelSelect
2ch product
Ach + Bch,
TrendSelect
Level, Trend
PatternSelect
Pattern in use
Ach Scale
0
Bch Scale
10000
CalcScale
AL Select
AL1~AL4:ON
PatternSelect
Pattern in use
Ach Scale
0
Bch Scale
10000
CalcScale
AL Select
AL1~AL4:ON
TimeAxis
1s/div
Brightness
5 Bright
PowerOnDelay
None
PowerSavingTime
None
MeasureMode
Default
D-ZeroRetention
Disable
Language
English
DisplayDirection
Horizontal
SettingProtect
Disable
AdjustProtect
Disable
10 sps
DisplayUpdateCycle
PatternCopy
---
SyncedAlarm
AL1~4:ON
RecordPos
BeforeAndAfter
Overwrite
Enable
UserDefaultSave
Save current settings as use initial values.
UserDefaultLoad
Initialize setting values to user initial values.
Initialize setting values to factoru default.
FactoryDefautLoad
Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
4th Layer (setting values)
Settable values
Pattern 1/2/3/4/5/6/7/8
None/Ach/Bch/Calc
Always/ExceptNearZero/OnStable
/ OnStableExceptNearZero/OnHold
LevelJudge/ZoneJudge/DiffJudge
Excess/LessThan
InTheZone/OutsideTheZone
Threshold: ±99999
Hysteresis: 0~99999
ZoneLowerLimit: ±99999
ZoneUpperLimit: ±99999
Hysteresis: 0~99999
ChangeAmount: 0~99999
DetectionInterval: 0.00~99.99[sec]
None/20ms/50ms/100ms/200ms/500ms
1s/5s/10s/20s
Normal/Latch/OneShot5ms/10ms/20ms
/50ms/0.1s/0.2s/0.5s/1s/2s
Positive/Negative
Black/Red/Yellow/Green
Pattern 1/2/3/4/5/6/7/8
0-10V/±10V/1-5V/0-20mA/4-20mA
None/Ach/Bch/Calc
0%: ±99999
100%: ±99999
Pattern 1/2/3/4/5/6/7/8
None/Ach/Bch/Calc
Positive/Negative
Positive/Negative
1~31
9600bps/19200bps/38400bps
None/Even/Odd
ModbusRTU/OriginalCommand/OriginalO
utput
9600bps/19200bps/38400bps
None/Even/Odd
7bit/8bit
1bit/2bit
CR / CR LF
Pattern 1/2/3/4/5/6/7/8
Ach/Bch/Calc/Ach+Comp/Bch+Comp
/Calc+Comp/Ach+Bch/Calc+A+B
Ach/Bch/Calc/Ach+Bch
Pattern 1/2/3/4/5/6/7/8
LowerLimit: ±99999
UpperLimit: ±99999
AL1/AL2/AL3/AL4
Pattern 1/2/3/4/5/6/7/8
LowerLimit: ±99999
UpperLimit: ±99999
AL1/AL2/AL3/AL4
100ms/div,1s/div,2s/div,5s/div,10s/div,
30s/div,60s/div120s/div
5Bright/4/3/2/1Dark/0 Off
None/2sec/5sec/10sec/20sec/30sec/60sec
None/1min/2min/5min/10min/30min/60mi
n
Default/Multi/WaveCompare
Disable/Enable
日本語/English
Horizontal/Vertical
Disable/Enable
Disable/Enable
10 sps/ 1 sps
Go to screen of pattern copy.
AL1/AL2/AL3/AL4
BeforeAlarm/BeforeAndAfter/AfterAlarm
Disable/Enable
120
Remarks
Select pattern No. to set.
Select a condition of comparion.
Only LevelJudge.
Only ZoneJudge.
Only LevelJudge.
Only ZoneJudge.
Compare ON/OFF after ActCondition is
kept certain time set here.
Select an output mode.
Select an output logic.
Select
a
background
color
alarming.
Select pattern No. to set.
Select a type of output range.
Select a ch referenced for analog output.
Scaling of analog output.
Set 0% and 100% value.
Select pattern No. to set.
Select a ch referenced for BCD output.
Select an output mode.
Select an output mode.
Set ID of the product.
Select a baudrate.
Select a type of parity bit.
Select a protocol.
Select a baudrate.
Select a type of parity bit.
Enable when Protocol is
OriginalCommand or OriginalOutput.
Select pattern No. to set.
*Bch and Calc is enable in 2ch product.
*Bch and Calc is enable in 2ch product.
Select pattern No. to set.
Set scale of level screen.
Select pattern No. to set.
Set scale of level screen.
Set time scale of division time.
Off means that whole of secreen is
turned off.
Set time that until measure after power
on.
Display is dark while power saving.
Whether remember D-Zero value or not.
Language.
Select a direction of screen.
Copy settings of pattern to other pattern.
IM-0883-01
when

Advertisement

Table of Contents
loading

Table of Contents