OPERATION INSTRUCTIONS
4. Push the igniter button until pilot flame is visible through the glass tube.
5. Once the pilot is lit, continue to depress the control knob for 30 seconds.
6. If the pilot does not stay lit, repeat steps 3 to 5.
7. If after repeating steps 3 to 5 unit does not light, then
-Push in control knob and turn counterclockwise to "PILOT" (
-As you are depressing the control knob, place long stem lighter
(not included) through the hole on the control panel to light the pilot. (Figure 3).
-Repeat step 5.
Figure 2
8. Push in and turn the control knob to the "HIGH" (
control knob. If you want a lower temperature, push in the control knob
and turn counterclockwise to the "LOW" (
Note: If pilot fails to remain lit, all valves should be closed and a waiting
period of at least 5 minutes should pass before attempting to light.
If you experience any ignition problem please consult "Troubleshooting" on page 20.
Caution: Avoid inhaling fumes emitted from the heater's first use. Smoke and odor from the burning
of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately 30
minutes. The heater should NOT produce thick black smoke.
Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the burner,
turn the control knob to the PILOT position. Then, turn the knob to the level of heat desired.
Figure 3
), then release
) (Figure 4).
16
) (Figure 2).
Figure 4