Cisco Nexus 9316D-GX Hardware Installation Manual

Cisco Nexus 9316D-GX Hardware Installation Manual

Nx-os mode switch
Table of Contents

Advertisement

Quick Links

Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation
Guide
First Published: 2018-03-12
Last Modified: 2019-12-23
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9316D-GX

  • Page 1 Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide First Published: 2018-03-12 Last Modified: 2019-12-23 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2018 Cisco Systems, Inc. All rights reserved.
  • Page 3: Table Of Contents

    Planning for Power Requirements Airflow Requirements Rack and Cabinet Requirements Clearance Requirements C H A P T E R 3 Installing the Chassis Safety Installation Options with Rack-Mount Kits, Racks, and Cabinets Airflow Considerations Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 4 Requirements Specific to Perforated Cabinets Cable Management Guidelines A P P E N D I X B System Specifications Environmental Specifications Switch Dimensions Switch and Module Weights and Quantities Transceiver and Cable Specifications Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Rack Mount Kit N3K-C3064-ACC-KIT Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 7: Preface

    Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 8: Documentation Feedback

    What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 9: Overview

    Overview, on page 1 Overview The Cisco Nexus 9316D-GX switch (N9K-C9316D-GX) is a 1-RU, fixed-port switch designed for deployment in data centers. This switch has 16 x 400/100-Gbps QSFP-DD ports. To determine how to use and configure these ports, see the...
  • Page 10 The following figure shows the hardware features seen from the port side of the chassis. Figure 1: Port Side View of the Cisco Nexus 9316D-GX Switch Chassis LEDs (Beacon [BCN], Status [STS], and...
  • Page 11 The following figure shows the hardware features seen from the power supply side of the chassis. Figure 2: Power Supply Side View of the Cisco Nexus 9316D-GX Switch Two power supplies (one for operations and one Out-of-band management port (RJ-45 port) for redundancy) (AC power supplies shown).
  • Page 12 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 13: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 14: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 15: Shock And Vibration Requirements

    For n+1 redundancy, you can use one or two power sources for the two power supplies. For n+n redundancy, you must use two power sources and connect each power supply to a separate power source. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 16: Airflow Requirements

    • Port-side exhaust airflow—Cool air enters the chassis through the fan and power supply modules in the cold aisle and exhausts through the port end of the chassis in the hot aisle. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 17: Rack And Cabinet Requirements

    Provide the chassis with adequate clearance between the chassis and any other rack, device, or structure so that you can properly install the chassis. Provide the chassis with adequate clearance to route cables, provide Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 18 Width of the front clearance area (equal to the width of the chassis with two rack-mount brackets that are attached to it). Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 19: Installing The Chassis

    Starting the Switch, on page 19 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
  • Page 20: Installation Options With Rack-Mount Kits, Racks, And Cabinets

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 21 This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective devices is rated not greater than 40A for the regular DC power supplies (rated 48-60VDC) and 10A for the HVDC power supplies. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 22: Unpacking And Inspecting The Switch

    • Burgundy (fan modules and power supplies) • Port-side exhaust airflow modules • Blue (fan modules and power supplies) All power supplies and fan modules must have the same direction of airflow. Note Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 23: Installing The Switch Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 24 (see the following figure). Tighten 12-24 screws to 30 in-lb (3.39 N·m) of torque and tighten 10-32 screws to 20 in-lb (2.26 N·m) of torque. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 25 Holding the chassis level, insert screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of six screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 26: Grounding The Chassis

    To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last. Before you begin Before you can ground the chassis, you must have a connection to the earth ground for the data center building. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 27: Starting The Switch

    • The switch must be adequately grounded. • The rack must be close enough to the dedicated power source so that you can connect the switch to the power source by using a designated power cables. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 28 If there is a safety cover for the terminals, place and secure it over the terminals to avoid an electrical shock hazard. e) Turn on the power at the circuit breaker for the DC power source. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 29 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 30 Installing the Chassis Starting the Switch Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 31: Connecting The Switch To The Network

    When running cables in overhead or subfloor cable trays, we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 32 Connect the other end of the RJ-45 rollover cable to the console or to a modem. What to do next You are ready to create the initial switch configuration (see Creating the Initial Switch Configuration, on page 25). Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 33: Creating The Initial Switch Configuration

    To connect the switch to the network, you can use the default choices for each configuration except the IP address, which you must provide. You can perform the other configurations later as described in the Cisco Nexus 9000 Series NX-OS Fundamentals Configuration Guide.
  • Page 34: Setting Up The Management Interface

    RJ-45 connectors. For longer connections, you can use an optical cable with SFP transceivers (LH or SX type). Note Use only one of these management ports—the switch does not support the use of both management ports. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 35: Connecting Interface Ports To Other Devices

    When removing transceivers from the switch, it is best to remove the optical cable first and then remove the transceiver. To determine which transceivers, adapters, and cables are supported by this switch, see the Cisco Transceiver Modules Compatibility Information document. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 36 Connecting the Switch to the Network Connecting Interface Ports to Other Devices Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 37: Replacing Components

    On the fan module that you are removing, press the two colored handles towards each other and pull the module part way out of its slot to unseat it from its connectors. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 38: Installing A Fan Module

    Step 2 Slide the fan module into the slot until it clicks in place. Step 3 Verify that the Status (STS) LED turns on and becomes green. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 39: Replacing A Power Supply Module

    Holding the replacement power supply with one hand underneath the module and the other hand holding the handle, turn the power supply so that its release latch is on the right side and align the back end of the power supply (the end Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 40: Replacing A High Voltage (Hvac/Hvdc) Power Supply

    Turn off the circuit breaker for the power feed to the power supply that you are replacing. Be sure that the LEDs turn off on the power supply that you are removing. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 41: Replacing A Dc Power Supply

    You can determine the airflow direction by looking at the coloring of the latch on each power supply. AC power supplies with burgundy latches have port-side intake airflow direction, and power supplies with blue latches have port-side exhaust airflow direction. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 42 Attach the power connector block end of the power cable to the electrical outlet on the front of the power supply. d) Turn on the circuit breaker for the power source. e) Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 43: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 44: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 45: System Specifications

    0 to 13,123 feet (0 to 4,000 meters) Switch Dimensions Switch Width Depth Height Cisco Nexus C9316D-GX 17.3 inches (43.9 cm) 25.5 inches (64.7 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 46: Switch And Module Weights And Quantities

    The following table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 47: Power Specifications

    Maximum hold-up time 12 ms at 1100 W Power supply output voltage 12 VDC Power supply standby voltage 12 VDC Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum certified) Form factor RSP1 Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 48: 1100-W Hvac/Hvdc Power Supply Specifications

    90 A (cold turn on) Maximum hold-up time 4 ms at 100% load Power supply output voltage 12 V/ 90A Power supply standby voltage 3.3 V/ 3A Efficiency rating @ -48VDC 94% at 50% load Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 49: Power Cable Specifications

    250 V, 10 A, 8.2 feet (2.5 m) Switzerland CAB-9K10A-SW 250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m) United Kingdom CAB-9K10A-UK 250 VAC, 10 A, BS1363 plug (13 A fuse), 8.2 (2.5 m) Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 50: Hvac/Hvdc Power Cables Supported By Aci-Mode And Nx-Os Mode Switches

    Saf-D-Grid and SD connectors CAB-HVAC-C14-2M HVAC 6.6-foot (2.0 m) cable with Saf-D-Grid and C14 connector (use for up to 240 V) CAB-HVAC-RT-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and RT connector Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 51: Dc Power Cable Specifications

    The 1100W DC power supply (NXA-PDC-1100W-PE/PI) is shipped with a connector already plugged into the power supply. Regulatory Standards Compliance Specifications The following table lists the regulatory standards compliance for the switch. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 52 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 53: Leds

    Temperature exceeds the minor alarm threshold. The switch is not receiving power. Green Fans and power supply modules are operational. Amber At least one fan or power supply module is not operating. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 54: Fan Module Leds

    Power supply is connected to a power source but not outputting power to the green switch. Green Flashing amber Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Slow power supply fan Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 55 Rotor fault Note This behavior occurs if the fan rotor is stopped during normal switch operation. Amber AC cord that is removed while in redundant mode (while other PSU is running). Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 56 LEDs LEDs Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 57: Additional Kits

    • M4 x 8-mm Phillips pan-head screws (2) Not applicable EAC Compliance document Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...
  • Page 58: Rack Mount Kit N3K-C3064-Acc-Kit

    Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus C9316D-GX NX-OS Mode Switch Hardware Installation Guide...

This manual is also suitable for:

N9k-c9316d-gx

Table of Contents