Global Fire Equipment ORION PLUS Operation Manual

Global Fire Equipment ORION PLUS Operation Manual

Fire alarm control panel
Hide thumbs Also See for ORION PLUS:

Advertisement

ORION PLUS – OPERATION MANUAL - 10/2017
OPERATION MANUAL
ORION PLUS
FIRE ALARM CONTROL PANEL
globalfire.pt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ORION PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Global Fire Equipment ORION PLUS

  • Page 1 ORION PLUS – OPERATION MANUAL - 10/2017 OPERATION MANUAL ORION PLUS FIRE ALARM CONTROL PANEL globalfire.pt...
  • Page 2: Table Of Contents

    ORION PLUS – OPERATION MANUAL - 10/2017 Index SECTION 1 - OPERATION Description of the fire control panel fascia ....................3 Alarm ................................. 6 Reset the system ............................7 Sound and silence the alarms – (Evacuation) ................... 7 Read the Fire, Fault, Test and Disabled queues ..................8 Active Delays .............................
  • Page 3: Section 1 - Operation

    ORION PLUS – OPERATION MANUAL - 10/2017 SECTION 1 - OPERATION 1.1 DESCRIPTION OF THE FIRE CONTROL PANEL FASCIA NOTE: Functions indicated as available to the General User do not require an access code to be entered. STATUS FIRE - If the LED is RED it indicates that there is a fire situation.
  • Page 4 ORION PLUS – OPERATION MANUAL - 10/2017 FAULTS ALARM FAULT - If the LED is AMBER it indicates that there is a problem with a loop sounder or conventional sounder circuit. This could be an open or short circuit. SUPPLY FAULT - If the LED is AMBER it indicates that there is a Primary Supply (Electrical mains) Fault, a Battery Fault or that there is an Earth Fault.
  • Page 5 ORION PLUS – OPERATION MANUAL - 10/2017 QUEUE REVIEW FIRE - If there is more than one FIRE pressing this button will display the next FIRE report on the LCD display for 20 seconds. Subsequent presses will step through all the FIRE reports. If the LED is flashing RED it means that there are FIRE reports to be reviewed.
  • Page 6: Alarm

    ORION PLUS – OPERATION MANUAL - 10/2017 1.2 ALARM (Authorized User Access) If the fire alarm control panel signals an ALARM the following events will take place: The sounders and other outputs will operate in accordance with their programming. The STATUS...
  • Page 7: Reset The System

    ORION PLUS – OPERATION MANUAL - 10/2017 1.3 RESET THE SYSTEM (Authorized User Access) This procedure should be used if: - There has been an alarm and the alarm condition no longer exists. - There has been a fault and the fault condition no longer exists.
  • Page 8: Read The Fire, Fault, Test And Disabled Queues

    ORION PLUS – OPERATION MANUAL - 10/2017 1.5 READ THE FIRE, FAULT, TEST AND DISABLED QUEUES (Access level 1 - General User) Fire, fault, test, and disabled messages are shown on the LCD display. The LCD has a limited display area. If more messages exist than can be shown on the LCD display the FIRE, FAULT, TEST or DISABLED LEDs illuminate on the QUEUE REVIEW area of the fascia.
  • Page 9: Active Delays

    ORION PLUS – OPERATION MANUAL - 10/2017 1.6 DELAYS ACTIVE (Authorized User Access) During installation, via the programming functions, delays can be set for the sounders. These delays are only active when the DELAYS ACTIVE LED is illuminated. At all other times the sounders will operate immediately when / if a fire is detected.
  • Page 10: Lamp Test

    ORION PLUS – OPERATION MANUAL - 10/2017 1.7 LAMP TEST (General User Access) This tests that all LEDs on the fascia are functioning, that the buzzer sounds properly and that the LCD display is fully functional. Press and hold the LAMP TEST button.
  • Page 11: Caretaker Test Mode

    ORION PLUS – OPERATION MANUAL - 10/2017 1.9 TEST MODE - (One-Man Walk-Through Test) - (Authorized User Access) Entry and Exit of Caretaker Test Mode Press the QUEUE REVIEW - TEST button first. Then the CONTROLS - LAMP TEST button momentarily.
  • Page 12 ORION PLUS – OPERATION MANUAL - 10/2017 Logging  Individual zones tests are not logged (they would fill the log very quickly)  Entry to Caretaker Test Mode is logged Zones Under Test  All detectors and call points in all Zones will be put into test mode...
  • Page 13: Disablements

    ORION PLUS – OPERATION MANUAL - 10/2017 1.10 DISABLEMENTS (Authorized User Access) 1.10.1 SELECTED ZONES Using the programming functions (see the ‘Installation & Commissioning Manual’) individual zones can be set for SELECTIVE DISABLEMENT. When the SELECTED ZONES button is activated those detectors will be disabled. (This may be required, for example, in a building with smoke detectors inside a room reserved for cigarette smokers.
  • Page 14: Sounders Disable

    ORION PLUS – OPERATION MANUAL - 10/2017 1.10.2 SOUNDERS DISABLE By pressing this button, all sounders on the system will be disabled. Its associated LED will light up. The DISABLED LED will also be lit. By pressing SOUNDERS DISABLE button once more, the LED will turn off and all sounders will re-enable.
  • Page 15: Enable/Disable Zones

    ORION PLUS – OPERATION MANUAL - 10/2017 1.10.4 ENABLE/DISABLE ZONES In order to Enable/Disable a zone follow the procedure described below: 1 - Enter either a valid User or Programming Code. 2 - Select Function 3.1 (Zones Disable/Assign), using the ▲▼ arrow keys. Press ENTER when menu 3 is reached.
  • Page 16 ORION PLUS – OPERATION MANUAL - 10/2017 GLOBAL FIRE EQUIPMENT S.A. Sítio dos Barrabés, Armazém Nave Y, Caixa Postal 908-Z, 8150-016 São Brás de Alportel - PORTUGAL Tel: +351 289 896 560 • Sales: sales@globalfire.pt • Technical Support: techs@globalfire.pt • www.globalfire.pt...