Summary of Contents for Global Fire Equipment Junior V4
Page 1
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 JUNIOR V4 FIRE ALARM CONTROL PANEL OPERATION & MAINTENANCE MANUAL VERSION - 07/2016 globalfire.pt...
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 CONTENTS SECTION 1 - OPERATION Description of the fire control panel fascia......................3 Alarm....................................6 Reset the system................................. 7 Sound and silence the alarms..........................7 Read the Fire, Fault, Test and Disabled queues....................
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 SECTION 1 - OPERATION 1.1 DESCRIPTION OF THE FIRE CONTROL PANEL FASCIA STATUS ZONES QUEUE REVIEW FIRE FIRE FAULT FIRE ALARM CONTROL PANEL...
Page 4
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 FAULTS ALARM FAULT If the LED is AMBER it indicates that there is a problem with a loop sounder or conventional sounder circuit. This could be an open or short circuit.
Page 5
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 QUEUE REVIEW FIRE If there is more than one FIRE pressing this button will display the next FIRE report on the LCD display for 20 seconds. Subsequent presses will step through all the FIRE reports.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.2 ALARM (Authorized User Access) If the fire alarm control panel signals an ALARM the following events will take place: The sounders, I/O modules and other outputs will operate in accordance with their programming.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.3 RESET THE SYSTEM (Authorized User Access) This procedure should be used if: - There has been an alarm and the alarm...
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.5 READ THE FIRE, FAULT, TEST AND DISABLED QUEUES (Access level 1 - General User) Fire, fault, test, and disabled messages are shown on the LCD display.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.6 DELAYS ACTIVE (Authorized User Access) STATUS ZONES QUEUE REVIEW FIRE FIRE FAULT FIRE ALARM CONTROL PANEL PRE-ALARM FAULT TEST TEST DISABLED SYSTEM ON MANUFACTURED IN THE E.U.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.7 LAMP TEST (General User Access) This tests that all LEDs on the fascia are functioning, that the buzzer sounds properly and that the LCD display is fully functional.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.8 PERFORM A FIRE DRILL (Access Level 2 or Authorized User Access) STATUS ZONES QUEUE REVIEW FIRE FIRE FAULT FIRE ALARM CONTROL PANEL...
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.9 CARETAKER TEST MODE - (One-Man Walk-Through Test) - Authorized User Access Entry and Exit of Caretaker STATUS ZONES QUEUE REVIEW Test Mode...
Page 13
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.9 CARETAKER TEST MODE (continued...) Logging Individual detector tests are not logged (they would fill the log very quickly) Entry to Caretaker Test Mode is logged...
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.10 DISABLEMENTS (Authorized User Access) STATUS ZONES QUEUE REVIEW FIRE FIRE FAULT FIRE ALARM CONTROL PANEL PRE-ALARM FAULT TEST TEST DISABLED SYSTEM ON MANUFACTURED IN THE E.U.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.10.2 SOUNDERS DISABLE STATUS ZONES QUEUE REVIEW By pressing this button, all sounders on FIRE FIRE the system will be disabled. FAULT...
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1.10.4 ENABLE / DISABLE ZONES In order to Enable/Disable a zone follow the procedure described below: 1 - Enter either a valid User or Programming Code.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 SECTION 2 - MAINTENANCE 2.1 SIM CARD REPLACEMENT This procedure is required when a software upgrade is supplied on a SIM CARD. The original SIM CARD also holds all the system configuration (settings) so this data must first be uploaded to a PC in order that it can be downloaded into the new SIM CARD once it has been fitted.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 2.2 REPLACING THE ELECTRICAL MAINS FUSE LIVE NEUTRAL EARTH MEANWELL MODEL: PS-45-27 DANGER 220 VOLTS 2.3 BATTERY VOLTAGE AND CHARGER CHECKS On the panel battery connector, measure the battery voltage. This should be 27.5V +/- 0.2V. Switch off the primary supply and check that the battery voltage does not drop significantly.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 1-3 Clear Historic Log Clears the Historic Log. 1-5 Read/Clear Autostart Count Every time the Panel's power is cycled, the Autostart count is incremented. SYSTEM RESETs from the front panel button do not increment the Autostart count.
Page 20
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 2.5 GETTING INTO PROGRAMMING MODE When the Panel is powered up it will be necessary to enter the panel programming mode. Familiarize yourself with this section before proceeding to the next section in the manual and powering up the panel.
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 2.6 LOGBOOK In accordance with EN54 part 14, it is the user's responsibility to maintain a logbook and to record all events resulting from or affecting the system.
Page 22
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 2.7 EVENT DATA SHEET DATE ACTION REQUIRED DATE TIME EVENT INITIALS COMPLETED globalfire.pt...
Page 23
Manufacturers of Fire Detection Equipment JUNIOR V4 - FIRE ALARM CONTROL PANEL OPERATING & MAINTENANCE MANUAL - 07/2016 GLOBAL FIRE EQUIPMENT S.A. Sítio dos Barrabés, Armazém Nave Y, Caixa Postal 908-Z, 8150-016 São Brás de Alportel - PORTUGAL Tel: +351 289 896 560 • Sales: sales@globalfire.pt • Technical Support: techs@globalfire.pt • www.globalfire.pt...
Need help?
Do you have a question about the Junior V4 and is the answer not in the manual?
Questions and answers