SXP118
Wiring Instructions
Wiring instructions for the Neutrik PowerCon True1 are as follows. Note that all mains wiring should be carried out by a competent, trained
technician. If a suitable technician is not available Martin Audio would recommend purchasing one of the range of pre-made mains
cables available as optional accessories. These feature the PowerCon True1 connector on a flexible cable of either 2.15m (part number
ASF12024) or 5m (part number ASF12023) in length and are terminated in a 16A male Ceeform connector. Both cables are rated to IP67.
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
A: Prepare cable as shown.
B: Place chuck over cable.
C: Wire the connector
Using a Torx T8 driver, the fixing screws
should be tightened to a torque value of
0.7Nm.
Live
Neutral
Ground
Copyright © 2019 Martin Audio Ltd.
VDE
EN 60320
250 V ac / 16A
H05VV-F3G 1.0mm², Length max. 2m
H05VV-F3G 1.5 – 2.5mm²
H07RN-F3G 1.5mm²
White Chuck
6.0 – 12.0 mm
Brown
Blue
Green/yellow
61
SX SERIES USER GUIDE
UL
UL 498 / C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White Chuck
6.0 – 12.0 mm
Black
White
Green
SX SERIES USER GUIDE V1.0