Finished With A Pool Liner - Pahlen WIDE User Manual

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 7
Skimmer WIDE
Installation of the pool wall made of stones/bricks, insulating blocks, concrete etc.,

finished with a pool liner

2
1
1
2
Installation as following:
NOTE! When casting/reinforcing the pool frame work, do not get closer than at least
50 mm to the stainless materials.
1. Make a hole for the skimmer in the framework, dimensions and placement as shown in
Figure 2.
2. Mount and secure the skimmer in the pool framework, position as shown in Figure 2.
3. The water surface should be at the centre of the opening and the flange of the skimmer
should be in line with a finished pool wall.
4. Make a hole in the frame work for the skimmer, see dimensions on Fig. 2.
5. Install and fix the skimmer.
The water level should be at the center of the opening and the flanges must lie at the
finished pool wall.
6. The openings are for level control, the overflow and refills are at the rear plugs if they
are not used.
7. Connect the cable (at least 6 mm²) with a ring from the ground point in the sealed
flanges to earth. Use stainless steel screw A4-quality for connection (Ø6,0 mm).
8. Connect the pipe coupling to the pool circulation pump with an appropriate thread
sealant.
9. Mask skimmer exposed flange and
openings before sealing in order to avoid
concrete splashes.
10. Attach self-adhesive packing onto the pipe
(after sealing).
11. Check that the flap cap is properly in place
and can move.
12. Add the pool liner.
13. Fill the pool with so much water that it
reaches 5 cm below the outflow pipe.
Turn off the water.
14. Cut a small incision in the pool liner in the
middle of the skimmer hole.
15. Install the outer packing and the mounting
frame - secure them first, then tighten
crosswise.
16. Cut clean the pool liner gently along the
front/inside of the mounting frame.
Continue to fill the water into the pool until
its level reaches the center of the skimmer
opening.
17. Install the front.
18. Adjust the skimmer to the desired height
in relation to the flooring around the pool.
Fix with attached straps.
NOTE! At eventual processing of the skimmer, the tools intended for stainless materials
should be exclusively used.
4
6
9
10
11
12
4
6
9
10
11
12
3
3
7
7
8
8
13
13
14
14
15
Fig 4.
15
Surface treatment
Designed by:
E
The tolerance class in accordance with this
Assembly drawing no.
part of ISO 2768-mK
Bräddavlopp WIDE
Installationsbild
poolstomme av isolerblock
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
1
2
1
1
Drawn by: Date
Approved by:
TK
2016-11-15
Art.no.
Scale
Revised by: Date
Drawing number
Rev.no.
M12626 0
9
ENGLISH
4
6
9
9
1
1
3
1
8
7
7
8
16
4
Fig 5.
1. Fixing strip with a screw M5x12
(2 pcs)
2. Skimmer top
Surface treatment
E
3. Grounding point
The tolerance class in accordance with this
part of ISO 2768-mK
Installationsbild bräddavlopp WM
4. Frame
För poolstomme av mursten
5. —
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
6. Self-adhesive packing 1,5mm
7. Wall mat
8. Liner
9. Packing 2mm
10. Mounting frame
11. Countersunk screw M5x12
(26 pcs)
12. Front
13. Reinforcing bar
14. Isolating block
15. Concrete
16. Bricks (leca block)
Fig 6. Wall of leca blocks
A
Flap cap
Klafflucka
A
Brick
Mursten
Grout
Puts
Fig 7. Frame of isolation blocks
Surface treatment
Designed by:
Drawn by: Date
E
The tolerance class in accordance with this
Assembly drawing no.
Art.no.
part of ISO 2768-mK
Scale
Installationsbild bräddavlopp WM
A
Flap cap
För poolstomme av mursten
Klafflucka
Drawing number
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
A
Isolation
Isolerblock
block
Surface treatment
Designed by:
Drawn by: Date
E
The tolerance class in accordance with this
Assembly drawing no.
Art.no.
part of ISO 2768-mK
Scale
Bräddavlopp WIDE
Installationsbild
Drawing number
poolstomme av isolerblock
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
10
11
12
1
1
1
Designed by:
Drawn by: Date
Approved by:
TK
2016-11-10
Assembly drawing no.
Art.no.
Revised by: Da
Scale
Drawing number
Re
M12625 0
Front
Front
Liner
Liner
Wall mat
Foam
Approved by:
TK
2016-11-10
Revised by: Date
Rev.no.
M12625 0
Front
Front
Liner
Liner
Wall mat
Foam
Approved by:
TK
2016-11-15
Revised by: Date
Rev.no.
M12626 0

Advertisement

Table of Contents
loading

Table of Contents