Workpiece and Work Area Set Up
1. Designate a work area that is clean and well lit.
The work area must not allow access by children
or pets to prevent distraction and injury.
2. Route power cord along a safe route to reach
the work area without creating a tripping hazard
or exposing the power cord to possible damage.
Power cord must reach the work area with enough
extra length to allow free movement while working.
3. There must not be objects, such as utility lines,
nearby that will present a hazard while working.
4. Clamp Pipe securely into proper Pipe Vise (sold
separately) to keep it from moving during threading.
5. Use Clamp assembly to secure and support
pipe during threading operation. Screw
Clamp Rod into Clamp. Make sure pipe
is secured to Clamp assembly and is
supported during threading operation.
6. Install Clamp Rod into Clamp Rod Slot. Ensure
Clamp Lever can be adjusted easily from above. Be
certain that pipe has enough clearance to proceed.
Page 10
For technical questions, please call 1-888-866-5797.
Note: Pipe end to be threaded must
be clean and chamfered.
7. Insert pipe into toothless end of Die.
Make sure inside diameter of Die matches
outside diameter of pipe. (See Figure B.)