EUCHNER MGB-L..B-PN Series Operating Instructions Manual

Safety systems with expanded data structure type c
Hide thumbs Also See for MGB-L..B-PN Series:
Table of Contents

Advertisement

Quick Links

Operating Instructions
Safety Systems
EN
MGB-L..B-PN.-... (PROFINET)
With Expanded Data Structure Type C
from V3.30.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGB-L..B-PN Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EUCHNER MGB-L..B-PN Series

  • Page 1 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) With Expanded Data Structure Type C from V3.30.1...
  • Page 2: Table Of Contents

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C Contents About this document ..................... 4 1.1. Scope ............................4 1.1.1. Notes on older product versions ..................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................
  • Page 3 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C Setup ......................... 22 13.1. Integrating into PROFINET and PROFIsafe ..................22 13.2. Replacement of an MGB system without programming device ............22 13.3. System reset to factory settings ....................22 13.4.
  • Page 4: About This Document

    Important! Always read all documents to gain a complete overview of safe installation, setup and use of the device. The documents can be downloaded from www.euchner.de. Enter the document number in the search box for this purpose. (translation of the original operating instructions) 2123622-04-06/19...
  • Page 5: Correct Use

    V2.0.0 or higher may be used. On the modification of system components, EUCHNER provides no warranty for function. The customer is responsible for the safe overall function, especially for the safe integration into the PROFIsafe environment.
  • Page 6: Exclusion Of Liability And Warranty

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 3. Exclusion of liability and warranty In case of failure to comply with the conditions for correct use stated above, or if the safety instructions are not followed, or if any servicing is not performed as required, liability will be excluded and the warranty void.
  • Page 7: General Safety Instructions

    Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. EUCHNER cannot provide any warranty in relation to the readability of the CD for the storage period required. For this reason you should archive a printed copy of the operating instructions.
  • Page 8: Function

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 5. Function 5.1. Locking module MGB-L2.B-PN. Together with a handle module, the locking module makes it possible to lock movable safety guards. The combination also serves as a mechanical door stop at the same time. Important! To operate the device as a guard lock according to EN ...
  • Page 9: Control Of Guard Locking

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 6. Control of guard locking By changing the parameters in the configuration tool of your control system, it can be set whether bit O 0.0 (in the safe data block for the MGB locking module) is evaluated as well (see chapter 13.7.4.
  • Page 10: System Overview

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 7. System overview Mounting plate Escape release (optional) (MGB-E…) Evaluation module (MGB-L…) Handle module (MGB-H…) Bus module (Profinet) (MGB-B…) Figure 1: Components at a glance NOTICE MGB-PN systems are completely factory configured. The configuration must not be changed subse- quently.
  • Page 11: Evaluation Module Mgb-L

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 7.2. Evaluation module MGB-L.- Key: 1 LED indicator 2 Cover for mechanical release 3 Locking arm (only for version with guard locking) 4 Auxiliary marking for max. permitted mounting distance Notice: Depending on the version, additional controls and indicators may be integrated into the cover.
  • Page 12: Mechanical Release

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 7.7. Mechanical release In the event of service, the guard locking can be released with the mechanical release irrespective of the state of the sole- noid (see Figure 6). Important! Ì...
  • Page 13: Lockout Mechanism

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 7.8. Lockout mechanism If the lockout mechanism is pivoted out/extended, the bolt tongue cannot be extended. The lockout mechanism can be secured with padlocks (see Figure 7). To pivot out, press the grooved part (only possible with bolt tongue retracted).
  • Page 14: Preparing Escape Release

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 7.9.1. Preparing escape release Profile width Length required for actuation Which EUCHNER parts are required? Necessary work steps axis Without With mounting mounting plates plates (4 mm each)
  • Page 15: Mounting

    Surface mounting Tip! Ì You can find an animation on the mounting process at www.mgb.euchner.de. Ì The color and labeling of pushbuttons and indicators can be modified. For mounting steps, see Figure 9 and Figure 10 to Figure 15.
  • Page 16: Mounting Color Cover

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C Figure 9: Installation example for door hinged on the right (general view) 8.1. Mounting color cover Mounting 90° Click! Removing Color cover (translation of the original operating instructions) 2123622-04-06/19...
  • Page 17: Changing Actuating Direction

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 9. Changing actuating direction (here: from right to left) Important! It is only possible to make this change when the bolt tongue is not extended and an escape release is not yet mounted.
  • Page 18: Protection Against Environmental Effects

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 3 mm CLOSED 9 Remove cover and undo hexagon socket head screw. OPEN AT Reposition door handle 90° in clockwise direction and fasten again. A Tighten hexagon socket head screw to 3 Nm. A...
  • Page 19: Controls And Indicators

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 11. Controls and indicators LEDs on the bus module Color Description 1 2 3 4 Binary coding of the DIP Link 1 and Green Bus plug inserted: switches for PROFIsafe Link 2 statically on...
  • Page 20: Electrical Connection

    Important! Ì The supply for further users on the bus may be forwarded via the Euchner MGB system. The entire supply current through the MGB must not be higher than specified in the chapter 16. Technical data on page 39.
  • Page 21: Notes About

    The mounting of conduits directly on the MGB is not allowed. Cables are only allowed to be connected via suitable cable glands. For this purpose use EUCHNER cable gland of type EKP- M20/06U. Equivalent cable glands can be used if they are UL-listed (QCRV) and are suitable for the related cable diameter (22 AWG –...
  • Page 22: Setup

    You will require the corresponding GSD file in GSDML format in order to integrate the MGB system: Ì GSDML-Vx.x-EUCHNER-MGB-PN_D_110026-JJJMMTT.xml You can find the GSD file in the download area at www.EUCHNER.de. Prior to commissioning, the GSD file must be imported into the configuration software of the control system (see control system manual).
  • Page 23: Mechanical Function Test

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.4. Mechanical function test It must be possible to easily insert the bolt tongue in the locking module. To check, close safety guard several times and actuate door handle. If available, check function of the escape release.
  • Page 24: Profinet Data Bytes For "Standard" And "Expanded" Data Structures (Data Blocks For Non-Safety-Related Functions)

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.6. PROFINET data bytes for “standard” and “expanded” data structures (data blocks for non-safety-related functions) Important! This device can be operated either in the “standard” or in the “expanded” configuration. Additional functions are available in the “expanded”...
  • Page 25: Data Block For "Standard" Mgb Bus Module

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.7.1. Data block for “standard” MGB bus module Required memory in data range of the control system (IO controller) MGB module Slot (refer to the data sheet of your device for the exact bit allocation) Bus module Switch (configuration example)
  • Page 26: Additional Button Functions (Only For Configuration With Expanded Data Structure)

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.7.3. Additional button functions (only for configuration with expanded data structure) Lamp control with MGB-PN in expanded mode Lamp Color Flashing White Bit H90 = 1 Bit H90 = 0 Door closed and not Door closed and White...
  • Page 27: Data Blocks Of Individual Functions At A Glance

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.8. Data blocks of individual functions at a glance Function data blocks are required for all additional functions that are not included in the data blocks for MGB modules. 13.8.1.
  • Page 28: Data Block For "Standard" Enabling Switch Function (Optional)

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.8.2. Data block for “standard” enabling switch function (optional) Required memory in data range of the control system (IO controller) Function Slot (refer to the data sheet of your device for the exact bit allocation) Enabling switch ES (en- Function...
  • Page 29: Data Block For "Standard" Diagnostics Function

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.8.5. Data block for “standard” diagnostics function Required memory in data range of the control system (IO controller) Function Slot (see below for exact bit allocation) Diagnostics Mechan- 272(6) 272(2)
  • Page 30: Data Block For "Expanded" Diagnostics Function

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.8.6. Data block for “expanded” diagnostics function Required memory in data range of the control system (IO controller) Function Slot (see below for exact bit allocation) Diagnostics Mechan- 272(6) 272(2)
  • Page 31: Profisafe Data Bytes (Data Block For Safe Functions)

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.9. PROFIsafe data bytes (data block for safe functions) Safe PROFIsafe data are transmitted in addition to the non-safety-related PROFINET data. These data include all information about the door position and guard locking, emergency stop and enabling switch, for example. Important! This device can be operated either in the “standard”...
  • Page 32: Data Block For "Standard" Profisafe

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.9.2. Data block for “standard” PROFIsafe Important! Ì Refer to the data sheet enclosed with your MGB system for the exact bit allocation. Use only bits that are specified according to the data sheet. Required memory in data range of the control system (IO controller) Function Slot...
  • Page 33: Expanded" Profisafe Data Bytes

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 13.9.3. “Expanded” PROFIsafe data bytes The “expanded” PROFIsafe data block includes all safe functions. It is subdivided as follows: Ì 2 input bytes of data for the functions (e.g. emergency stop switch position) Ì...
  • Page 34 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C Bit allocation for 1st byte Description Description SI0.0 Emergency stop SO0.0 Guard locking solenoid – control voltage on (function identical to bit O0.0 in data block for MGB evaluation module L0, L1 or L2 =>...
  • Page 35 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C Bit allocation for 3rd byte Description SI2.0 NHQ This is set if bit NH is set the falling edge is detected on bit S91 the falling edge is detected in bit ENR. This is reset when the emergency stop button is pressed.
  • Page 36: Diagnostic Messages Of The Mgb System

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 14. Diagnostic messages of the MGB system All diagnostic messages are listed below. The scope of the possible messages can differ according to the MGB system version. PROFIsafe messages Test-pulse error (short-circuit monitoring detected an error) Display via LED BF (see Figure 16 on page 19)
  • Page 37 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C General messages of the overall system Description Measures/remedying errors 274 (1) Max. (mech.) life exceeded Message via input bit I0.7 Message cannot be reset 274(2) Internal device error Please contact our support orga- nization! 274(3)
  • Page 38: System Status Table

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 15. System status table LEDs on interlocking/locking module (translation of the original operating instructions) 2123622-04-06/19...
  • Page 39: Technical Data

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 16. Technical data NOTICE If a product data sheet is included with the product, the information on the data sheet applies. Parameter Value max. door position 65 mm Housing material Fiber glass reinforced plastic;...
  • Page 40: Troubleshooting

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 17. Troubleshooting 17.1. Latching fault when actuating the escape release In order to achieve monitoring of the locking device in category 4, PL e according to EN ISO 13849-1, an internal monitoring logic system is integrated into every locking module.
  • Page 41: Service

    Loss of the safety function because of damage to the system. In case of damage, the affected module must be replaced completely. Only accessories or spare parts that can be ordered from EUCHNER may be replaced. Regular inspection of the following is necessary to ensure trouble-free long-term operation: Ì...
  • Page 42: Declaration Of Conformity

    Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 20. Declaration of conformity (translation of the original operating instructions) 2123622-04-06/19...
  • Page 43 Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C 2123622-04-06/19 (translation of the original operating instructions)
  • Page 44 MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C from V3.30.1 (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 04/2019 Subject to technical modifications; no responsibility is accept- ed for the accuracy of this information.

This manual is also suitable for:

Mgb-l2.b-pn series

Table of Contents