Mitsubishi Electric SLZ Series Technical & Service Manual page 23

Split-type, heat pump air conditioners
Hide thumbs Also See for SLZ Series:
Table of Contents

Advertisement

7-6. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
Each function is controlled by the dip switch on control P.C. board.
Model setting and capacity setting are memorised in the nonvolatile memory of the indoor controller board.
Switch
Functions
Capacity
SW2
setting
Function
SW3
setting
• Function setting becomes effective when the Dip switch SW3-5 is ON.
* Switch off SW3-5 when the function setting is done by wired remote controller.
OCH564
Setting by the DIP switch
Model
Setting
1 2 3 4 5
SLZ-KA25VAL3
1 2 3 4 5
SLZ-KA35VAL3
1 2 3 4 5
SLZ-KA50VAL3
Dip switch
Function
Power failure
SW3-1
automatic recovery
Set temperature in
SW3-2
heating mode (4 deg up)
Fan speed when the
SW3-3
thermostat is OFF
(during heating mode)
SW3-4
SW3-5*
SW3 function
23
The black square (
ON
OFF
ON
OFF
ON
OFF
Action by switch opration
OFF
ON
OFF
ON
Available
Not available
Extra low
Stop
Not available
Available
) indicates a switch position.
Remarks
<Initial setting>
SW3
1 2 3 4 5
ON
OFF