NXR-901
Receiver Section
Item
Condition
1 MCF
1) Narrow
Tracking generator
Output: –20dBm
Spectrum analyzer
Frequency: 73.05MHz
Span: 50kHz
2. Discriminator 1) Narrow
Frequency: Desired frequency
SSG output: –53dBm (501µV)
SSG MOD: 1kHz
SSG DEV: 1.5kHz
AF output: 2V/4
3. RD Level
1) Channel spacing
: Analog Narrow
Connect the SSG to the RX
ANT.
SSG setting
Frequency: Desired frequency
Output: –53dBm (501µV)
MOD: 1kHz
DEV: ±1.5kHz
4. RA Level
1) Channel spacing
: Analog Narrow
Connect the SSG to the RX
ANT.
SSG setting
Frequency: Desired frequency
Output: –53dBm (501µV)
MOD: 1kHz
DEV: ±1.5kHz
5. Receiver
1) Channel spacing
Sensitivity
: Analog Narrow
Check
Connect the SSG to the RX
ANT.
SSG setting
Frequency: Desired frequency
MOD: 1kHz
DEV: ±1.5kHz
AF: 0.45V/4
6. RF AGC
1) Channel spacing
: Analog Narrow
SSG setting
Frequency: Desired frequency
MOD: OFF
Level: 0dBm
2) Channel spacing
: Analog Narrow
SSG setting
Frequency: Desired frequency
MOD: OFF
Level: –25dBm
86
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Tracking
RX
CN46
RX
generator
Spectrum
CN47
analyzer
SSG
Rear
RX ANT
RX
AF VM
TEST/
SPKR
jack SPO
(pin 12)
4 load
SSG
Rear
RX
AF VM
ANT
CON-
TROL
I/O jack
RD (pin
10)
SSG
Rear
RX
AF VM
ANT
CON-
TROL
I/O jack
RA (pin
11)
SSG
Rear
RX
Distortion
ANT
meter
TEST/
SPKR
jack
SPO
(pin 12)
4 load
SSG
Rear
RX
Spectrum
RX
ANT
analyzer
CN68
Adjustment
Parts
Method
L232
Adjust it to look like
Refer to Fig. 1. (Page 80)
L246
the wave in fi gure 1.
L286
Adjust AF output
max.
PC
80mV
±5mV
ADJ
PC
400mV
±20mV
ADJ
Check
–115dBm (0.4µV) or less
Measure 12dB SINAD SSG
level to use squelch adjust-
ment.
PC
Value: 128
Measure CN68 terminal level
ADJ
: –38dBm~–26dBm
Check
Measure CN68 terminal level
: –45dBm~–40dBm
Specifi cations / Remarks