Kenwood NXR-901 Service Manual page 80

900mhz digital base-repeater ocxo unit kxk-3 m3
Hide thumbs Also See for NXR-901:
Table of Contents

Advertisement

NXR-901
Flat cable (36-pin) about 256mm (E37-0979-05)
Test Signaling
■ Analog
No.
RX (Decode Signaling)
1
None
2
None
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 210.7Hz
6
QT 254.1Hz
7
DQT D023N
8
DQT D754I
9
None
10
None
11
DTMF Decode (Code: 159D) DTMF Encode (Code: 159D)
12
None
13
None
■ NXDN
No.
RX (Decode Signaling)
1
RAN1
2
RAN1
3
RAN1
Signaling number 1 is used for link test.
Signaling number 2 is used for TX modulation signal
quality test. i.e, TX adjacent channel power, FSK error,
Occupied bandwidth, Emission mask, etc.
Signaling number 3 is used for TX deviation test. If the
modulation mode is very narrow, the modulation fre-
quency is 600Hz. If the modulation mode is narrow, the
modulation frequency is 1200Hz.
80
ADJUSTMENT
TX (Encode Signaling)
None
100Hz Square Wave
QT 67.0Hz
QT 151.4Hz
QT 210.7Hz
QT 254.1Hz
DQT D023N
DQT D754I
CWID Encode (ID: VVV)
Single Tone
DTMF Encode (Code: 9)
Courtesy Tone
TX (Encode Signaling)
RAN1
PN9
Maximum deviation pattern
10dB/div
3.75kHz
3dB max.
12.5kHz
Center frequency: 73.05MHz
Span: 50kHz
Pass bandwidth: ±3.75kHz at 3dB
Fig. 1
3.75kHz
More than
25dB
12.5kHz

Advertisement

Table of Contents