The stove position must be chosen in accordance with the environment, the waste pipe and the chimney flue.
Verify with the local authority if there are restrictive rules about the air intake for combustion purposes and
ventilation of domestic environment and about the waste fumes pipes plant with chimney flue and chimney
pot. The manufacturer declines any responsibility in case of installation not in accordance with the standards
in force, with a not correct ventilation system, an electrical connection not in accordance with the standards in
force, or in case of bad use of the appliance. The installation must be carried out by a qualified technician
who will sign a declaration of conformity of the system and take all responsibility for the installation and good
functioning of the appliance. A booklet of testing and periodic maintenance to be carried out by the installer is
issued to the client together with the stove.
Installation
Installation
Installation
Installation
The appliance should be installed on a floor with adequate load bearing capacity. If the existing structure
does not satisfy this requirement it is essential to take appropriate precautions (e.g. install a load distribution
plate). When the appliance is installed it should be placed so as to allow easy access for cleaning the stove
itself, the exhaust gas ducts and the chimney flue.
The pellets stove must be installed in isolation, with a minimum air space of 15 cm to allow an adequate
cooling of the appliance and a good distribution of heat in the domestic environment. In compliance with fire-
prevention methods there must be a minimum distance of at least 20 cm from flammable objects (sofas,
furniture, wooden covering) to the back and side of the stove and of 80 cm to the front where the fire door is.
If the floor is made of flammable material you must prepare a coverage made of non-flammable material
(plate of steel, marble, refractory material), which sticks out 50 cm from the front of the stove where the fire
door is and 20 cm from the other sides (see picture 10). You can't install the stove in bedrooms or
bathrooms.
Electrical connection
Electrical connection
Electrical connection
Electrical connection
Important: the appliance must be installed by specialised staff. The electrical connection must be carried out
using the supplied cable, adding an adequate plug on a socket which can take the load factor and voltage
specific of each model as indicated on the technical data table (see page 17), the plug must be accessible
when the appliance is installed. It is necessary that the fixed power grid is protected with a single pole switch
to assure a complete disconnection with a minimum opening between the contacts of 3 mm. Make sure there
is an efficient grounding, if there isn't one or it is inefficient you should provide to have a grounding installed
in compliance with the standards in force.
N.B. The stove heating system is protected by two fuses located inside the main switch behind the stove.