  • Page 1 Maintenance And Use Manual Pellets Stove Pellets Stove Pellets Stove Pellets Stove...
  • Page 2: Table Of Contents

    European legislation. Installation should be carried out by skilled personnel, who will take complete responsibility for final installation and for consequent correct operation of the installed product. Fair will not be liable in the event of failure to respect these instructions.
  • Page 3: Packing

    Pellets Stove • PACKING PACKING PACKING PACKING Packing Packing Packing Packing The packing includes a cardboard box, which is recyclable in accordance with RESY guidelines, some recyclable inserts made of expanded EPS and wooden pallet. All package materials can be used again for similar use or taken away as solid urban waste in accordance with the regulation in force.
  • Page 4 Pellets Stove underneath it there must be a chamber to collect solid residuals and condensate with a height not inferior to 50 cm and accessible through an airtight metal door. An expert stove setter should verify the chimney flue efficiency and if it is necessary the chimney flue must be ducted with materials in accordance to the standards in force.
  • Page 5 Pellets Stove and animals from going inside. The height of the fumes outlet in the atmosphere must be far away from the reflux area caused by the roof shape or by the presence of nearby obstacles (see picture 4). Maintenance Maintenance Maintenance Maintenance...
  • Page 6 Pellets Stove Pic. 5 Maximum capacity of electric ventilation(m Net additional section (cm Up to 50 Over 50 and up to 100 Over 100 and up to 150 Pic. 6 Air necessary for combustion Air necessary for combustion Air necessary for combustion Air necessary for combustion All types of combustion need air (oxygen).
  • Page 7 Pellets Stove Pic. 7 The air intake must be at a distance of: Doors, windows, fume exhaust, air 1.5 m Below spaces etc. Doors, windows, fume exhaust, air 1.5 m Level with spaces etc. Doors, windows, fume exhaust, air 0.3 m Above spaces etc.
  • Page 8: Fuel

    Pellets Stove Examples of correct installation Examples of correct installation Examples of correct installation Examples of correct installation 1) Installation with hole on the roof for the passage of the pipe using an adequate mineral insulator (rock wool, ceramic fibre with a density bigger than 80 kg/m ).
  • Page 9: Installation

    Pellets Stove • INSTALLATION INSTALLATION INSTALLATION INSTALLATION Introduction Introduction Introduction Introduction The stove position must be chosen in accordance with the environment, the waste pipe and the chimney flue. Verify with the local authority if there are restrictive rules about the air intake for combustion purposes and ventilation of domestic environment and about the waste fumes pipes plant with chimney flue and chimney pot.
  • Page 10: Use

    Pellets Stove External thermostat connection External thermostat connection External thermostat connection External thermostat connection The stove starts thanks to a thermostat placed on its back, make sure you verify its position and don’t place it near any kind of heating source. If you wish you can connect the stove to any kind of external environment thermostat.
  • Page 11 Pellets Stove Introduction Introduction Introduction Introduction It is recommended to follow the hereunder guidelines for the best functioning and least consumption. If the installation is well carried out and the fumes pipe is efficient the lightning of the pellets will be very easy. The procedure is as following: empty and clean the brazier, verify there are enough pellets in the tank.
  • Page 12 Pellets Stove stoke pellets and the resistance will keep warming up. When the temperature is high enough, thanks to the fume gas feeler, the electronic gear case (after 7-10 minutes) will consider the starting phase ended and start the next phase of flame stabilisation displaying “FirE on” and starting the tangential ventilator (heat exchanger).
  • Page 13 Pellets Stove Weekly programming Weekly programming Weekly programming Weekly programming You can plan the daily starting and switching off of the stove for 7 Days with 4 different programs. Remember pressing P4 you can exit from any program at any time you wish. The parameters of the clock-thermostat are: UT01 to set the current date and the use modality (OFF means the exclusion of programming).
  • Page 14: Safety Devices

    Pellets Stove The remote control operates with a 12 Volt MN21 type battery. The batteries should be removed from the device before it is disposed of and must themselves be disposed of safely. Carry out the following operations to change the batteries: - use a screwdriver to loosen the screw on the back of the remote control;...
  • Page 15: Maintenance

    Pellets Stove Energy black out alarm Energy black out alarm Energy black out alarm Energy black out alarm After an energy black out “AlAr no rEtE” will appear on display. The fumes extractor will clear up the fumes residuals for 20 minutes starting the switching off phase. When cooled down, verify the occurring problem on page 20.
  • Page 16 Pellets Stove Open the door only when the stove is off. Clean it sucking the ash left inside. After cleaning repeat the opposite operation to make sure of the good conditions and efficiency of the strip and when necessary replace it. Firebox cleaning Firebox cleaning Firebox cleaning...
  • Page 17: Technical Data

    Pellets Stove • TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA Characteristics Characteristics Characteristics Characteristics Descrizione Descrizione Descrizione Descrizione ZC12 ZC12 ZC12 ZC12 M M M M C10 Width 50,2cm 50,2cm 50,3cm 47,4cm 50,3cm 47,4cm Depth 50,6cm 50,6cm 50,6cm 50,6cm 50,6cm 50,6cm Height...
  • Page 18 Pellets Stove Wiring diagram Wiring diagram Wiring diagram Wiring diagram...
  • Page 19 Pellets Stove...
  • Page 20: If There Is A Problem

    Pellets Stove • IF THERE IS A PROBLEM IF THERE IS A PROBLEM IF THERE IS A PROBLEM IF THERE IS A PROBLEM Problem Problem Problem Problem Cause Cause Cause Cause Solution Solution Solution Solution • The control panel • The stove hasn’t got electrical input •...
  • Page 21 Pellets Stove stove fitter to check the chimney from the stove outlet to the chimney pot). Have it cleaned immediately. • Clean the stove inside (see Maintenance) • Pellets can burn thanks to the chimney flue depression without the aspirator. Have it replaced immediately (cod.
  • Page 22 Pellets Stove technician • Replace the card, cod Com0231. Call a specialised technician • Call an expert stove setter to verify if the chimney is according to the law (see paragraph 2) • When there is a very strong wind a negative depression to the chimney can occur.
  • Page 23: Guarantee

    The same applies in the event that the staff of the Technical Service Centre or of Fair srl discover while doing repairs that the date of installation/first startup is not the true one (which can be detected from identifying details and other elements in the equipment).
  • Page 24 Pellets Stove Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Company Company Company Company Mr/Ms. Mr/Ms. Mr/Ms. Mr/Ms. Street Street Street Street Postcode Postcode Postcode Postcode Town Town Town Town State te te te Tel.
  • Page 25 Pellets Stove Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Work done on: Work done on: / / / / Work done on: Work done on: Material used: Guarantee User’s signature Segnature of TSC Specialised T Specialised Technical Servicing Centre echnical Servicing Centre...
  • Page 26 Pellets Stove Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Work done on: Work done on: / / / / Work done on: Work done on: Material used: Guarantee User’s signature Segnature of TSC Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre...
  • Page 27 Pellets Stove...
  • Page 28 FAIR s.r.l. Via Lago di Costanza, 24 – 36015 Schio – VI – ITALIA Tel. 0445 698000 – Fax 0445 698100 e-mail: info@fair-europe.com - http://www.fair-europe.com...

This manual is also suitable for:

S6Z12Zc12M10Mc10

Table of Contents