FAIR S7 Maintenance And Use Manual page 21

Table of Contents

Advertisement

• The exchanger fan
keeps working when
the stove is cold
• Hash around the stove
• The stove switches off.
Alarm displayed "AlAr
no rEtE"
• The stove is in steady
condition, the display
shows: "RiS"
• When working normally
the stove display
shows "Stop Fire"
• The stove switches off.
Alarm displayed: "AlAr
dEP"
Pellets Stove
• Temperature fumes feeler is faulty
• Electronic card is faulty
• Faulty or damaged doors strips
• Fumes pipe tubes are not airtight
• Plug accidentally unplugged
• Temporary power failure
• Faulty electronic card
• Environment temperature reached
• Fumes outlet temperature reached
• Cleaning grate
• The door isn't closed
• The waste outlet is obstructed
• Fumes extractor is damaged
• Rubber connection is obstructed
• Pressure switch is faulty
• Electronic card is faulty
• Excessive chimney length
• Bad weather conditions
stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
• Clean the stove inside (see
Maintenance)
• Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
• Replace the fumes feeler, cod
Com0239. Call a specialised
technician
• Replace the card, cod Com0231.
Call a specialised technician
• Replace the strips cod.
Com0244+Com0245
• Seal immediately the pipe fitting
(with high temperature silicone)
and/or replace the pipes with new
ones. Fumes pipes that aren't
airtight can be dangerous for your
health. Call an expert stove fitter.
• Verify the plug is plugged in
• Verify the power failure and start the
stove again
• Replace the card, cod Com0231.
Call a specialised technician
• The stove works at minimum rate: no
problem
• The stove works at minimum rate: no
problem
• The stove goes to minimum and
extraction ventilation to maximum:
no problem
• Closed the door properly and check
the door strips are in good
conditions otherwise replace them
cod. Com0244+Com0245
• The fumes waste chimney is partially
or totally obstructed (call an expert
stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
• Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
• Take the silicone pipe off and with
the help of a pointed tool clean the
bodying hole. Replace the pipe if
necessary cod. Com0401
• Replace the pressure switch, cod
Com0233. Call a specialised
21
21
21
21