• The stove switches
OFF. Alarm displayed
"AlAr Sic"
• The stove switches off.
Alarm displayed "AlAr
hottemp"
• The stove switches off.
Alarm displayed "AlAr
Sond"
Pellets Stove
• Stove overheated
• The exchanger fan doesn't work
• Temporary power failure
• Faulty thermostat
• Air filter obstructed
• Faulty electronic card
• Fumes feeler is faulty
• Electronic card faulty
• The environment exchanger fan
doesn't work
• Too high parameter set on card during
phase 5
• Fumes temperature feeler
disconnected
• Fumes temperature feeler is faulty
technician
• Replace the card, cod Com0231.
Call a specialised technician
• Call an expert stove setter to verify if
the chimney is according to the law
(see paragraph 2)
• When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again
• Let the stove cool down and stoke it
again, if the problem continues call a
specialised technician
• Replace the fan, cod Com0237. Call
a specialised technician
• A voltage failure during the
functioning of the stove causes an
overheating of the boiler and it is
necessary to stoke it again and start
the stove.
• Replace the thermostat, cod
Com0238. Call a specialised
technician
• Clean the filter (see Maintenance)
• Replace the card, cod Com0231.
Call a specialised technician
• Replace the feeler, cod Com0239.
Call a specialised technician
• Replace the card, cod Com0231.
Call a specialised technician
• Replace the fan, cod Com0237. Call
a specialised technician
• Call a specialised technician to
regulate the pellets stoke
• Verify the feeler is connected to the
card and/or put in and blocked in the
seat of the extractor. Call a
specialised technician
• Replace the feeler, cod Com0239.
Call a specialised technician