External thermostat connection
External thermostat connection
External thermostat connection
External thermostat connection
The stove starts thanks to a thermostat placed on its back, make sure you verify its position and don't place it
near any kind of heating source. If you wish you can connect the stove to any kind of external environment
thermostat. In that case you must use a cable of 2x0,5 mm2, make it go through the pre-set hole under the
tank and connect it to the electronic card (see wiring diagram pag.18). These operations must be carried out
by a specialised technician.
Digital or mechanical thermostat
Digi
Digi
Digi
tal or mechanical thermostat
tal or mechanical thermostat
tal or mechanical thermostat
It is possible for the apparatus to control the ambient temperature by means of a digital thermostat that
serves to reduce the heating power to minimum when a preset temperature is reached.
When the stove has been started off and it is in normal operation mode display A will show a number (21 C
for example); this value is the ambient temperature.
Buttons P1 or P2 are used to enter thermostat setting mode and the display will show a message that will
alternate with the word "set" and the temperature setting; pressing P2 will decrease this value while pressing
P1 will increase it.
After adjusting to the desired temperature wait until the message "set" disappears from the display.
Use buttons P4 and P5 to adjust the desired heating power.
When the apparatus reaches the temperature setting it will automatically pass to operation at the lowest
heating power and LED 4 will go off.
If you wish to disable digital thermostat operation, using P3 take the temperature to maximum so that the
message "Hot" appears on display A. The remote control can also be used to perform the same operations.
Ventilation
Ventilation
Ventilation
Ventilation
The stove is provided with a ventilation system with dust filter. The air vented by the moto-ventilators keeps
the stove temperature low preventing the materials the stove is made of from excessive stress and heating
the domestic environment more homogeneously. Make sure you periodically test if the ventilator works
properly. After removing the humidifying glass you can connect a pipe (diameter 8 cm) to vent some of the
heated air to an other room. It is recommended that the pipe length doesn't exceed 3 meters not to loose the
efficacy of the heated air.

• USE

USE
USE
USE
Basic instructions
Basic instructions
Basic instructions
Basic instructions
The stove that you have bought uses fuel in pellets. This type of material is made of natural wood chips from
the wood processing industry. A special process that requires neither binders nor additives is used to
compress the chips in industrial machinery at high pressure so that they become solid wood pellets. Use of
raw materials that have not been made into pellets is ABSOLUTELY PROHIBITED in our stove.
Failure to respect this instruction will invalidate all guarantees and may have a negative affect on the safety
of the apparatus.
For the first two or three times when you light the stove, bear in mind the following advice:
- Children should not be present, because the vapours emitted by the stove may be harmful to health. Adults
should also avoid staying for long near the stove.
- Do not touch the surfaces as they may still be unstable.
- Air the room well several times.
-The surfaces will be fully hardened after several heating processes.
- Operate the stove at medium Power for 2-3 days (display A will show the number 3) so that the mechanical
parts are able to settle into smooth running.
Important
Continuous operation of the stove at maximum power may shorten the expected life of the electrical
components, we therefore advise against it. We suggest using the stove at maximum power only at the start,
in order to bring the room quickly to the desired temperature (for an hour and a half for example).
The stove is designed for using pellets with a diameter of 6-7 mm. If you need to use pellets of different
diameters, an authorised servicing engineer must first take it away for adjustment.