Technical Index; Model Description; Certification; Model - Veilux SVEX-T500A User Manual

Explosion proof camera
Table of Contents

Advertisement

2- Technical Index

2.1 Model Description

SV

2.2 Certification

Explosion-proof mark

2.3 Model

SVEX-T500A

2.4 Electrical Index

Input voltage
Input voltage range
Operating current
Camera power supply
Heater
Power consumption
Electrical connection
EX
T500
II 2 GD Ex d II C T6 Gb
Ext III C T80°C Db
Explosion-proof camera, with wiper, long type
220VAC/110VAC/24VAC 50/60Hz (24V is a special type;
please specify when ordering)
± 10%
≤2A
12VDC (provided by external equipment)
Started at the temperature below -10º C± 5 º C
30W
2-core cable for power supply
4-core cable for lens control
Video cable for video signal output
SVEX-T500A Explosion Proof Camera User Manual.
A
Blank: with wiper / -1: without wiper
/A: with wiper / -1/A: without wiper
Design serial number
Product code
Company code
B 为短形护
5

Advertisement

Table of Contents
loading

Table of Contents