1- Overview

Designed and manufactured strictly according to the standards such as GB3836.1-2010
Explosive atmospheres - Part 1: Equipment - General requirements, GB3836.2-2010
Explosive atmospheres - Part 2: Equipment protection by flameproof enclosure "d",
GB12476.1-2000 Electrical apparatus for use in the presence of combustible dust - Part 1-1:
Electrical apparatus protected by enclosures and surface temperature limitation - Specification
for apparatus, EN60079-0:2009 Explosive atmospheres - Part 0: Equipment - General
requirements, EN60079-1:2007 Explosive atmospheres - Part 1: Equipment protection by
flameproof enclosure "d", and EN 60079-31:2009 Explosive atmospheres - Part 31: Equipment
dust ignition protection by enclosure "t", SVEX-T500 series explosion-proof camera has
the enclosure of all stainless steel structure with the level of protection up to IP66, and can
be widely used in the fields of petroleum, chemical industry, wharf, port, mine, aerospace,
aviation, military industry and grain processing, etc.
SVEX-T500 series explosion-proof camera has 4 specifications, including long type in
which zoom lens cameras can be installed, and short type in which fixed lens cameras or
integrated cameras can be installed.
Relevant technical data, patterns and prototypes of SVEX-T500 series explosion-proof
camera (hereinafter referred to as the camera) have been reviewed to be qualified by
the China National Quality Supervision and Test Centre for Explosion Protected Electrical
Products (CQST).