Description Of Explosion-Proof Structure; Troubleshooting - Veilux SVEX-T500A User Manual

Explosion proof camera
Table of Contents

Advertisement

4-

Description of Explosion-proof Structure

Various special circumstances are adequately considered during structural design, so that
no explosion will occur in the environment full of explosive mixture outside the equipment
if sparks are generated in the equipment; moreover, the explosion-proof performance of
the equipment is guaranteed from the following aspects: enclosure strength, gap between
components, and highest surface temperature limitation of enclosure.
The explosion-proof enclosure after finish machining must be able to withstand the
hydraulic test pressure specified in GB3836.2: 2.0MPa, not less than 10s, judged as
qualified in case of no water dripping and intact structure.
The highest surface temperature of enclosure shall not exceed +80º C during normal
operation.
The lead-in device for the camera is fastened with the hold-down nut.
The sight window of the camera is made of tempered glass, and thus can withstand the
impact and thermal shock tests.

5- Troubleshooting

Failure
Wiper
problem
No image
Cause
Stuck wiper
Dead corners
Open-circuit power
supply
Open-circuit signal line
Damaged camera
Faulty lens
SVEX-T500A Explosion Proof Camera User Manual.
Solution
Adjust the wiper shaft
Check the wiring
Check the wiring
Replace the camera
Replace the lens
Remark
Return to Veilux for
repair
DYI
DYI
DYI
Return to Veilux
for repair
Return to Veilux
for repair
13