Download Print this page

MasterCool 70053 Operating Instructions

Flaring and swaging tool

Advertisement

Quick Links

WARNING
WARNING
WARNING! Wear safety goggles when using this tool!
Wear Safety Goggles
Wear Safety Goggles
Avoid Contact with Refrigerant
Avoid Contact with Refrigerant
FLARING
FLARING
1. Make sure the flaring cone is securely attached to the yoke screw.
1. Make sure the flaring cone is securely attached to the yoke screw.
2. Insert an evenly cut piece of tubing into the corresponding sized
2. Insert an evenly cut piece of tubing into the corresponding sized die. Insert tubing so
die. Insert tubing so that it is slightly above the top of the die.
that it is slightly above the top of the die.
3. Tighten the wing nut closest to the tube first, then tighten the
3. Tighten the wing nut closest to the tube first, then tighten the other one. Nuts must be
other one. Nuts must be securely tightened so there is no chance
securely tightened so there is no chance of the tube slipping.
of the tube slipping.
4. Slide the yoke over the bar and line up flaring cone with tube.
4. Slide the yoke over the bar and line up flaring cone with tube. Slightly turn the yoke
Slightly turn the yoke clockwise to lock into place. Secure this
clockwise to lock into place. Secure this locked position with thumb and forefinger
locked position with thumb and forefinger and begin to tighten
and begin to tighten down the yoke screw until desired flare is achieved.
down the yoke screw until desired flare is achieved.
SWAGING
SWAGING
1. Remove yoke cone and install the proper size spreader on the yoke screw. Note that
the small spreader accommodates 3/16", 1/4" and 3/8" O.D. tubing.
1. Remove yoke cone and install the proper size spreader on the
yoke screw. Note that the small spreader accommodates 3/16",
2. Insert an evenly cut piece of tubing into the corresponding sized die. Insert tubing
1/4" and 3/8" O.D. tubing.
approximately 1/8" more than the size (O.D.) of the tube you are swagging. (i.e. on
1/2" O.D. tubing, the tubing should protrude 5/8" past the face of the bar).
2. Insert an evenly cut piece of tubing into the corresponding sized
die. Insert tubing approximately 1/8" more than the size (O.D.) of
the tube you are swagging. (i.e. on 1/2" O.D. tubing, the tubing
should protrude 5/8" past the face of the bar).
OPERATING INSTRUCTIONS
70053 FLARING AND SWAGING TOOL
INSTRUCTIONS FOR USING FLAR
Visit us at www.TestEquipmentDepot.com
"World Class Quality"
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
70053
1

Advertisement

loading

Summary of Contents for MasterCool 70053

  • Page 1 OPERATING INSTRUCTIONS WARNING 70053 FLARING AND SWAGING TOOL WARNING WARNING! Wear safety goggles when using this tool! Wear Safety Goggles INSTRUCTIONS FOR USING FLAR 70053 Wear Safety Goggles Avoid Contact with Refrigerant Avoid Contact with Refrigerant FLARING FLARING 1. Make sure the flaring cone is securely attached to the yoke screw.
  • Page 2 Secure this locked position with thumb and forefinger 5. Tighten the yoke screw until the chamber on the upper shoulder of the spreader is bearing on the tube. PARTS LIST 70053-PB 70053 7/16 1/4 1/8 3/16 5/16 3/8 70153 70451 70553 �������...