"Change Separator" Light (Flashing Or On Steadily) On Startup; "Change Separator" Light (Flashing Or On Steadily) While Running; "Motor Oveload" Shutdown - Gardner Denver Electra-Screw EDEQHF Operating And Service Manual

Stationary base-mounted compressors - 40/50 hp
Table of Contents

Advertisement

Symptom
Possible Cause
Remedy
"CHANGE SEPARATOR" light
1. Separator differential is
(FLASHING OR ON Steadily)
greater than 8 psid (.5 Bars).
CHANGE SEPARATOR" light
WHILE RUNNING)
"MOTOR OVERLOAD"
shutdown.
2. Bad Transducer.
3. Misadjusted minimum
pressure valve.
4.
Sticky
minimum pressure
valve.
5. Defective minimum
pressure valve.
[Won't set at 65 psig (4.5 Bars)]
1.
Separator differential is
greater than 8 psid (.5 Bars).
2. Electrical noise creating
false readings.
3. Oil reservoir is overfilling.
4. Unit is rapidly cycling.
5. Defective transducer.
6. Plugged aftercooler,
due
to freezing or varnishing.
1. Running compressor at a
pressure over nameplate
pressure.
2.
Incoming voltage low or
high.
3.
Imbalance
voltage
(check phase to phase).
1.
Change Separator.
2. Verify readings with mechan-
ical gauges. If defective,
replace with 88H1 98.
3. Set minimum pressure valve at
65 psig (4.5 Bars).
4. Disassemble and clean.
5. Rebuild or replace.
1. Change Separator.
2. Make
sure transducer
wires
are kept to a minimum length
and are twisted.
3. Fill to proper level (center of
the green range).
4. Adjust subtractive pilot.
See Service
Memo #248.
(Add subtractive
pilot if
unit does not have one.)
5. Verify readings with mechan-
ical gauges.
If defective,
replace with 88H1 98.
6.
Clean or replace aftercooler.
1. Lower pressure to nameplate.
2. Consult your power company.
3.
If imbalance
exceeds
5%,
check incoming power.
13-8-610