Addition Of Oil Between Changes; Approximate Oil System Capacities - Gardner Denver Electra-Screw EDEQHF Operating And Service Manual

Stationary base-mounted compressors - 40/50 hp
Table of Contents

Advertisement

2.
3.
4.
5.
6.
-
Dump Oil from filter and reinstall used filter.
Fill system with a 50 percent charge of the new
lubricant:
-
Start machine and stay there to observe.
-
Allow machine to run about five minutes at
temperature,
or until temperature stabilizes,
then shut down.
Thoroughly drain machine.
Change to new filter and separator.
Fill system with full charge of the new lubricant.
Machine should then be run normallv. however.
total run time after the initial changeoUt should be
50 percent of normal anticipated service life of the
new lubricant.
-
Drain all lubricant from system, change filter
and separator, and replace with full charge of
the new lubricant.
cAuTION
improper equipment maintenance with
use of synthetic lubricants will damage
equipment.
Oil filter and oil separator
change
intervals remain the same as
for AEON 'M 4000 -- See maintenance
schedule, Section 8.
DANGER
Oil under pressure
will cause severe
personal
injury or death. Shut down
compressor
and relieve system of all
pressure,
disconnect,
tag and lockout
pOWer
supply
to the starter
before
removing valves, caps, plugs, fittings,
bolts and filters.
WARNING
I
High temperature
operation can cause
damage
to equipment
or personal in-
jury. Do not repeatedly restart after high
temperature
stops operation. Find and
correct the malfunction before resum-
ing operation.
AWARNING
All materials
used in Gardner
Denver
compressor
units are compatible
with
AEON 'M 9000 SP Lubricating Coolant.
Use caution
when
selecting
down-
stream
components
such as air line
lubricating
bowls, gaskets
and valve
trim.
AEON 'M9000 SP Synthetic Lubricant is
not compatible
with low nitrile Buna N
or acrylic paints. AEON 'M 9000 SP is
compatible with most air system down
stream components.
Material Safety Data Sheets (MSDS) are available for all
AEON lubricants from your authorized Gardner Denver
distributor or by calling
217-222-5400.
COLD AMBlENT
OPERATION
- See "installation for
Cold Weather Operation," Section 2, page 2.
ADDITION
OF OIL BETWEEN
CHANGES
must be
made when the oil
level is at the bottom of the red range
on the gauge as read while the unit is running.
To add oil, follow these steps:
1.
Be sure the unit is completely off and that no air
pressure is in the oil reservoir.
2.
Disconnect, tag and Iockput the power supply to
the starter.
3.
Wipe away all dirt around the oil filler plug.
4.
Remove the oil filler plug and add oil as reuuired to
return the oil level to thE center of the green range.
40& 50 HP
Refill Capacity For Normal Oil Change ....... ......................................................................................5.5 U.S. Gallons
Red To Yellow Range ......................................................................................................................l.25
U.S. Gallons
FIGURE 5-2-
APPROXIMATE OIL SYSTEM CAPACITIES
13-8-610
Section
5